<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Evoked Potentials (EP) &#8211; Compumedics Neuroscan</title>
	<atom:link href="https://compumedicsneuroscan.com/applications/ep/feed/" rel="self" type="application/rss+xml" />
	<link>https://compumedicsneuroscan.com</link>
	<description>World Leader in Functional Neuro-imaging</description>
	<lastBuildDate>Thu, 10 Apr 2025 09:56:16 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	
	<item>
		<title>CURRY 9 X &#8211; Data Acquisition and Online Processing</title>
		<link>https://compumedicsneuroscan.com/product/curry-9-x-data-acquisition-and-online-processing/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Thu, 23 Dec 2021 15:45:10 +0000</pubDate>
				<guid isPermaLink="false">https://compumedicsneuroscan.com/?post_type=product&#038;p=7503</guid>

					<description><![CDATA[The CURRY 9 X Data Acquisition package is an easy-to-use and reliable tool for EEG data recording and online processing. All the features required for data acquisition are supported; for instance impedance check, online filtering, real-time event averaging, real-time fMRI/TMS artefact correction and many more. Using the TCP/IP interface, data is immediately available to other packages (for instance Matlab) and allows for BCI applications.

CURRY data files are fully compatible with EEGLAB.]]></description>
										<content:encoded><![CDATA[<p>The CURRY Neuroimaging Suite software is divided into several modules that can stand alone or work together to maximize your lab’s flexibility. The Acquire and Online Signal Processing package consists of all primary features and functions needed for acquiring high-quality EEG/EP/ERP data and online/real-time processing.</p>
<p>Acquisition in CURRY is enhanced with easier, more flexible, and more advanced tools for on-line data processing, with up to 512 channels and sampling rates up to 20 kHz.</p>
<p>CURRY will support EEG data acquisition with <a href="/products/by-name/synamps-2-rt/">SynAmps 2/RT</a>, <a href="http://compumedicsneuroscan.com/product/siesta-wireless-eeg-amplifier/">Siesta</a>, NuAmps, <a href="/products/by-name/neuvo/">Neuvo</a>, <a href="/products/by-name/grael/">Grael</a>, and E-Series <a href="/products/amplifiers/">amplifiers</a>. Each amplifier has its own set-up image to ensure ease of use in setting the system.</p>
<p>Online Artifact Reduction for up to five types of artifact can be applied simultaneously, letting you verify the quality of the data while the subject is still connected. Artifacts include blinks, pulse artifact, MR gradient artifact, ballistocardiogram, and bad blocks. Reduction methods include Subtraction, Covariance, PCA, and ICA.</p>
<p>On-line averaging is enhanced, with the ability to extract both standard TTL triggered and conditional averages. Averages can be overlaid and compared directly on-line. Data processing can be applied and those optimized parameters can be saved for off-line application.</p>
<p>Impedance testing is available without interrupting data acquisition, and is provided in a simple visual display with values for each electrode.</p>
<p>Stream live to Matlab or via TCP/IP protocol (listener CURRY, Matlab, custom software), suitable for Brain Computer Interface (BCI) and related applications.</p>
<p>The start and stop of recording, and the impedance test procedure can be controlled through the stimulus presentation software.</p>
<p>CURRY data files are compatible with EEGLAB.</p>
<p>Convert recordings into other formats (such as EDF or CNT) from within the acquisition software.</p>
<p><a href="https://compumedicsneuroscan.com/wp-content/uploads/CURRY-Package-Information-Card-2023.pdf">CURRY Package Information Card</a></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>STIM2 &#8211; precise stimulus presentation</title>
		<link>https://compumedicsneuroscan.com/product/stim2-precise-stimulus-presentation/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Mon, 07 Nov 2016 19:11:59 +0000</pubDate>
				<guid isPermaLink="false">http://compumedicsneuroscan.com/?post_type=product&#038;p=5491</guid>

					<description><![CDATA[<strong>STIM2</strong> is Compumedics Neuroscan’s stim­u­lus presen­ta­tion and exper­i­men­tal design system. Operating under Windows, <strong>STIM2</strong> provides a familiar and simple interface to design and deliver stimuli with ease and, more importantly, accuracy. STIM2 provides complete control of the experiment, while delivering the highest quality stimuli.

<strong>STIM2</strong> is a complete soft­ware envi­ron­ment for custom stim­u­lus and task design as well as presen­ta­tion. The <strong>STIM2</strong> system can be inte­grated in fMRI, MEG, and other func­tional neuro-imaging appli­ca­tions. The soft­ware provides a famil­iar menu-driven inter­face in which to design and present visual and audi­tory stim­u­la­tion paradigms.

<strong>STIM2</strong>’s power­ful and intu­itive design trans­lates into a short learn­ing curve and quick imple­men­ta­tion. The modules make it easy to design and execute your stim­uli with the great­est preci­sion, and the wide array of pre-packaged stim­uli ensures fast inte­gra­tion into your research.
<p class="p1"><strong>STIM<span class="s1">2 </span></strong>is fully integrated with the Cedrus StimTracker. This system uses photocells and auditory threshold detection to identify stimulus onset with the greatest accuracy possible.</p>]]></description>
										<content:encoded><![CDATA[<p><strong>STIM2 Modules</strong></p>
<p>STIM2 is comprised of 14 modules includ­ing a generic program­ma­ble exper­i­ment control module (Gentask), a sound file editor, and an image file converter. Other modules are cate­go­rized into Motor, Percep­tual, Atten­tion, Memory, and Cogni­tive func­tions, many of which have neuropsy­cho­log­i­cal paral­lels (Tapping, Stroop, Cate­gories, Card Sort­ing, etc.). The Gentask program includes an inter­face for creat­ing and present­ing almost any type of visual, audi­tory, or combined task and record­ing behav­ioral responses. Gentask has been used for a vari­ety of exper­i­ments includ­ing audi­tory P300, N400, MMN, CNV, picture memory, and many more. The Gentask Editor makes creat­ing, modi­fy­ing and debug­ging sequences files very easy. The Sound Editor program is used for record­ing, edit­ing, and present­ing digi­tal sound segments. The Image Converter module will convert less famil­iar formats into commonly encoun­tered types of graph­ics files (BMP, JPG, PNG, TIF, etc.) that can then be presented.</p>
<p><strong>STIM2</strong> inter­faces seam­lessly with CURRY 7 and SCAN, as well as any of our ampli­fiers: SynAmps RT, Neuvo, NuAmps and Grael.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Neuvo 256-channel Amplifier</title>
		<link>https://compumedicsneuroscan.com/product/neuvo-256-channel-eeg-erp-ep-amplifier/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Wed, 26 Oct 2016 14:18:01 +0000</pubDate>
				<guid isPermaLink="false">http://compumedicsneuroscan.com/product/neuvo-256-channel-amplifier/</guid>

					<description><![CDATA[The <strong>Neuvo</strong> is well suited to meet the needs of any Neuroscience laboratory. Build on the technology of the SynAmps RT, the Neuvo is an EEG, ERP and EP amplifier with very high specifications at a competitive price.

<strong>Neuvo</strong> sets a new standard in amplifier technology, providing a system suitable for recording everything from high sampling rate (10,000 Hz) Auditory Brain Stem recordings and Spike Spindles to true DC recordings of CNV and P300.

The <strong>Neuvo</strong> can be used in conjunction with the <strong>CURRY</strong> software, providing a complete acquisition and analysis system, or with the ACCESS SDK, allowing user’s custom built software to control and acquire data from the system.

<strong>Neuvo</strong> can also be used with the <strong>STIM2</strong> system for integrated and accurate stimulus presentation or will accept TTL pulses from third party systems.

<strong>Neuvo</strong> can be used with the <strong>QuikCap</strong>, to provide fast and simple electrode placement or will accept any touch proof electrode as well. Grid, depth and microelectrodes may also be used with the Neuvo.

The <strong>Neuvo</strong> system has CE Class IIa medical certification and FDA approval.]]></description>
										<content:encoded><![CDATA[<p><strong>Channel Count Per Headbox: 64 Monopolar and 4 Bipolar</strong><br />
Utilizing the latest technology, Neuvo allows for discrete monopolar and bipolar channels, enhancing the flexibility of recordings. Linking headboxes together allows more than 500 channels to be recorded.</p>
<p><span style="text-decoration: underline;">A 256-channel Neuvo EEG system has four headboxes, with 272 channels in total</span>.</p>
<p><strong>Maximum Sampling Rate: 10,000 Per Channel all channels driven</strong><br />
Faster sampling rates allow for more accurate sampling of the analog data being recorded. Signals such as Auditory Brain Stem Response require these faster rates, while typical ERP measures benefit from increased resolution.</p>
<p><strong>Sampling Method: All Channels Sampled Simultaneously</strong><br />
Current technology eliminates the problems associated with sample and hold circuits. Utilizing a dedicated 24-bit A to D chip for each channel, the Neuvo enhances resolution and accuracy of each sample by ensuring a more valid measure of the data without decay or skew.</p>
<p>The 24-bit resolution allows for even the most subtle differences in amplitude to be measured accurately.</p>
<p><strong>Recording Bandwidth: DC to 3500 Hz</strong><br />
Many slow potentials (i.e., P300, MMN, CNV) have components that can only be measured accurately using a DC amplifier. DC amplifiers are also not subject to the AC coupled, filter time constant that distorts recordings after an artifact. The high frequency end of the Neuvo&#8217;s range allows for more accurate recording of the fastest frequencies.</p>
<p><strong>Active Noise Cancellation: Utilizing advanced driven reference technology</strong><br />
Neuvo sets a new standard for amplifier design, both in terms of safety and signal quality. Actively sampling environmental noise, and applying an antiphase signal to eliminate that noise, elevates the CMRR to unprecedented levels. This technology also provides increased patient protection.</p>
<p><strong>&gt;10 G Ohm Input Impedance: Allows standard impedance or fast preparation to be obtained</strong><br />
Neuvo allows you to choose on a subject by subject basis to prepare the scalp electrode impedance to the scientifically accepted levels or to record with high impedance, due to time or bject constraints. This flexibility allows you the option to maximize your data collection for each subject and collect the best data the situation allows.</p>
<p><strong>Portability and Integration: Small Package, big features</strong><br />
Digital amplifiers are typically small and thus portable, but portability also means unpredictable environmental noise. Neuvo has built in technology to function even in the worst electromagnetic fields.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Neuvo 128-channel Amplifier</title>
		<link>https://compumedicsneuroscan.com/product/neuvo-128-channel-eeg-erp-ep-amplifier/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Wed, 26 Oct 2016 14:07:26 +0000</pubDate>
				<guid isPermaLink="false">http://compumedicsneuroscan.com/product/neuvo-128-channel-amplifier/</guid>

					<description><![CDATA[The <strong>Neuvo</strong> is well suited to meet the needs of any Neuroscience laboratory. Build on the technology of the SynAmps RT, the Neuvo is an EEG, ERP and EP amplifier with very high specifications at a competitive price.

<strong>Neuvo</strong> sets a new standard in amplifier technology, providing a system suitable for recording everything from high sampling rate (10,000 Hz) Auditory Brain Stem recordings and Spike Spindles to true DC recordings of CNV and P300.

The <strong>Neuvo</strong> can be used in conjunction with the <strong>CURRY</strong> software, providing a complete acquisition and analysis system, or with the ACCESS SDK, allowing user’s custom built software to control and acquire data from the system.

<strong>Neuvo</strong> can also be used with the <strong>STIM2</strong> system for integrated and accurate stimulus presentation or will accept TTL pulses from third party systems.

<strong>Neuvo</strong> can be used with the <strong>QuikCap</strong>, to provide fast and simple electrode placement or will accept any touch proof electrode as well. Grid, depth and microelectrodes may also be used with the Neuvo.

The <strong>Neuvo</strong> system has CE Class IIa medical certification and FDA approval.]]></description>
										<content:encoded><![CDATA[<p><strong>Channel Count Per Headbox: 64 Monopolar and 4 Bipolar</strong><br />
Utilizing the latest technology, Neuvo allows for discrete monopolar and bipolar channels, enhancing the flexibility of recordings. Linking headboxes together allows more than 500 channels to be recorded.</p>
<p><span style="text-decoration: underline;">A 128-channel Neuvo EEG system has two headboxes, with 136 channels in total</span>.</p>
<p><strong>Maximum Sampling Rate: 10,000 Per Channel all channels driven</strong><br />
Faster sampling rates allow for more accurate sampling of the analog data being recorded. Signals such as Auditory Brain Stem Response require these faster rates, while typical ERP measures benefit from increased resolution.</p>
<p><strong>Sampling Method: All Channels Sampled Simultaneously</strong><br />
Current technology eliminates the problems associated with sample and hold circuits. Utilizing a dedicated 24-bit A to D chip for each channel, the Neuvo enhances resolution and accuracy of each sample by ensuring a more valid measure of the data without decay or skew.</p>
<p>The 24-bit resolution allows for even the most subtle differences in amplitude to be measured accurately.</p>
<p><strong>Recording Bandwidth: DC to 3500 Hz</strong><br />
Many slow potentials (i.e., P300, MMN, CNV) have components that can only be measured accurately using a DC amplifier. DC amplifiers are also not subject to the AC coupled, filter time constant that distorts recordings after an artifact. The high frequency end of the Neuvo&#8217;s range allows for more accurate recording of the fastest frequencies.</p>
<p><strong>Active Noise Cancellation: Utilizing advanced driven reference technology</strong><br />
Neuvo sets a new standard for amplifier design, both in terms of safety and signal quality. Actively sampling environmental noise, and applying an antiphase signal to eliminate that noise, elevates the CMRR to unprecedented levels. This technology also provides increased patient protection.</p>
<p><strong>&gt;10 G Ohm Input Impedance: Allows standard impedance or fast preparation to be obtained</strong><br />
Neuvo allows you to choose on a subject by subject basis to prepare the scalp electrode impedance to the scientifically accepted levels or to record with high impedance, due to time or bject constraints. This flexibility allows you the option to maximize your data collection for each subject and collect the best data the situation allows.</p>
<p><strong>Portability and Integration: Small Package, big features</strong><br />
Digital amplifiers are typically small and thus portable, but portability also means unpredictable environmental noise. Neuvo has built in technology to function even in the worst electromagnetic fields.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Neuvo 64-channel Amplifier</title>
		<link>https://compumedicsneuroscan.com/product/neuvo-64-channel-eeg-erp-ep-amplifier/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Wed, 26 Oct 2016 13:43:49 +0000</pubDate>
				<guid isPermaLink="false">http://compumedicsneuroscan.com/product/neuvo-64-channel-amplifier/</guid>

					<description><![CDATA[The <strong>Neuvo</strong> is well suited to meet the needs of any Neuroscience laboratory. Build on the technology of the SynAmps RT, the Neuvo is an EEG, ERP and EP amplifier with very high specifications at a competitive price.

<strong>Neuvo</strong> sets a new standard in amplifier technology, providing a system suitable for recording everything from high sampling rate (10,000 Hz) Auditory Brain Stem recordings and Spike Spindles to true DC recordings of CNV and P300.

The <strong>Neuvo</strong> can be used in conjunction with the <strong>CURRY</strong> software, providing a complete acquisition and analysis system, or with the ACCESS SDK, allowing user’s custom built software to control and acquire data from the system.

<strong>Neuvo</strong> can also be used with the <strong>STIM2</strong> system for integrated and accurate stimulus presentation or will accept TTL pulses from third party systems.

<strong>Neuvo</strong> can be used with the <strong>QuikCap</strong>, to provide fast and simple electrode placement or will accept any touch proof electrode as well. Grid, depth and microelectrodes may also be used with the Neuvo.

The <strong>Neuvo</strong> system has CE Class IIa medical certification and FDA approval.]]></description>
										<content:encoded><![CDATA[<p><strong>Channel Count Per Headbox: 64 Monopolar and 4 Bipolar</strong><br />
Utilizing the latest technology, Neuvo allows for discrete monopolar and bipolar channels, enhancing the flexibility of recordings. Linking headboxes together allows more than 500 channels to be recorded.</p>
<p><span style="text-decoration: underline;">A 64-channel Neuvo EEG system has one headbox, with 68 channels in total</span>.</p>
<p><strong>Maximum Sampling Rate: 10,000 Per Channel all channels driven</strong><br />
Faster sampling rates allow for more accurate sampling of the analog data being recorded. Signals such as Auditory Brain Stem Response require these faster rates, while typical ERP measures benefit from increased resolution.</p>
<p><strong>Sampling Method: All Channels Sampled Simultaneously</strong><br />
Current technology eliminates the problems associated with sample and hold circuits. Utilizing a dedicated 24-bit A to D chip for each channel, the Neuvo enhances resolution and accuracy of each sample by ensuring a more valid measure of the data without decay or skew.</p>
<p>The 24-bit resolution allows for even the most subtle differences in amplitude to be measured accurately.</p>
<p><strong>Recording Bandwidth: DC to 3500 Hz</strong><br />
Many slow potentials (i.e., P300, MMN, CNV) have components that can only be measured accurately using a DC amplifier. DC amplifiers are also not subject to the AC coupled, filter time constant that distorts recordings after an artifact. The high frequency end of the Neuvo&#8217;s range allows for more accurate recording of the fastest frequencies.</p>
<p><strong>Active Noise Cancellation: Utilizing advanced driven reference technology</strong><br />
Neuvo sets a new standard for amplifier design, both in terms of safety and signal quality. Actively sampling environmental noise, and applying an antiphase signal to eliminate that noise, elevates the CMRR to unprecedented levels. This technology also provides increased patient protection.</p>
<p><strong>&gt;10 G Ohm Input Impedance: Allows standard impedance or fast preparation to be obtained</strong><br />
Neuvo allows you to choose on a subject by subject basis to prepare the scalp electrode impedance to the scientifically accepted levels or to record with high impedance, due to time or bject constraints. This flexibility allows you the option to maximize your data collection for each subject and collect the best data the situation allows.</p>
<p><strong>Portability and Integration: Small Package, big features</strong><br />
Digital amplifiers are typically small and thus portable, but portability also means unpredictable environmental noise. Neuvo has built in technology to function even in the worst electromagnetic fields.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SynAmps RT 256-channel Amplifier</title>
		<link>https://compumedicsneuroscan.com/product/synamps-rt-256-channel-eeg-erp-ep-amplifier/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Tue, 25 Oct 2016 07:13:00 +0000</pubDate>
				<guid isPermaLink="false">http://compumedicsneuroscan.com/product/synamps-rt-256-channel-amplifier/</guid>

					<description><![CDATA[<strong>SynAmps RT</strong> is the one of the latest EEG, ERP and EP amplifier from Compumedics Neuroscan. Using the most current technology, the RT builds on the quality of the past SynAmps series of amplifiers and extends the specifications beyond anything that has come before.

<strong>SynAmps RT</strong> sets a new standard in amplifier technology, providing a system suitable for recording everything from high sampling rate (20,000 Hz) Auditory Brain Stem recordings and Spike Spindles to true DC recordings of CNV and P300.

The <strong>SynAmps RT</strong> also serves as the recommended platform for recording in the MRI and MEG, in conjunction with the <strong>Micro MagLink RT</strong> system. SynAmps RT includes clock synchronization circuitry, allowing the amplifier to synch with other devices, such as MR scanners, more precisely, without the need for very fast acquisition rates.

<strong>SynAmps RT</strong> can be used in conjunction with the <strong>CURRY</strong> software, providing a complete acquisition and analysis system, or with the ACCESS SDK, allowing user’s custom built software to control and acquire data from the system.

<strong>SynAmps RT</strong> can also be used with the <strong>STIM2</strong> system for integrated and accurate stimulus presentation or will accept TTL pulses from third party systems.

<strong>SynAmps RT</strong> can be used with the <strong>QuikCap</strong>, to provide fast and simple electrode placement or will accept any touch proof electrode as well. Grid, depth and microelectrodes may also be used with the SynAmps RT.

The <strong>SynAmps RT</strong> system has CE Class IIa medical certification and FDA approval.]]></description>
										<content:encoded><![CDATA[<p><strong>Channel Count Per Headbox: 64 Monopolar, 4 Bipolar, 2 High Level</strong><br />
Utilizing the latest technology, SynAmps RT allows for discrete monopolar and bipolar channels, enhancing the flexibility of recordings. Additional high level inputs are isolated to allow voltage level signals to be merged with the physiological data. Linking headboxes together allows more than 500 channels to be recorded.</p>
<p><span style="text-decoration: underline;">A 256-channel SynAmps RT EEG system consists of four headboxes, with 280 channels in total</span>.</p>
<p>A fully isolated, programmable bipolar excitation supply is also provided capable of supplying up to +/- 10VDC at 100mA to external bridges or measurement devices.</p>
<p><strong>Maximum Sampling Rate: 20,000 Per Channel all channels driven</strong><br />
Faster sampling rates allow for more accurate sampling of the analog data being recorded. Signals such as Auditory Brain Stem Response require these faster rates, while typical ERP measures benefit from increased resolution.</p>
<p><strong>Sampling Method: All Channels Sampled Simultaneously</strong><br />
Current technology eliminates the problems associated with sample and hold circuits. Utilizing a dedicated 24-bit A to D chip for each channel, the SynAmps RT enhances resolution and accuracy of each sample by ensuring a more valid measure of the data without decay or skew.</p>
<p>The 24-bit resolution allows for even the most subtle differences in amplitude to be measured accurately.</p>
<p><strong>Recording Bandwidth: DC to 3500 Hz</strong><br />
Many slow potentials (i.e., P300, MMN, CNV) have components that can only be measured accurately using a DC amplifier. DC amplifiers are also not subject to the AC coupled, filter time constant that distorts recordings after an artifact. The high frequency end of the SynAmps RT&#8217;s range allows for more accurate recording of the fastest frequencies.</p>
<p><strong>Active Noise Cancellation: Utilizing advanced driven reference technology</strong><br />
SynAmps RT sets a new standard for amplifier design, both in terms of safety and signal quality. Actively sampling environmental noise, and applying an antiphase signal to eliminate that noise, elevates the CMRR to unprecedented levels. This technology also provides increased patient protection.</p>
<p><strong>Recording in fMRI Environments: Integration with the Micro MagLink RT System</strong><br />
The same amplifier that is used in standard recording environments can also be used to record EEG data in the MRI by interfacing to the Micro MagLink RT system. SynAmps RT was built with enough input range and accuracy to sample both the EEG and the fMRI artifact with sufficient resolution to remove the artifact and ensure the EEG is left intact.</p>
<p><strong>&gt;10 G Ohm Input Impedance: Allows standard impedance or fast preparation to be obtained</strong><br />
SynAmps RT allows you to choose on a subject by subject basis to prepare the scalp electrode impedance to the scientifically accepted levels or to record with high impedance, due to time or subject constraints. This flexibility allows you the option to maximize your data collection for each subject and collect the best data the situation allows.</p>
<p><strong>Portability and Integration: Small Package, big features</strong><br />
Digital amplifiers are typically small and thus portable, but portability also means unpredictable environmental noise. SynAmps RT has built in technology to function even in the worst electromagnetic fields. Custom solutions such as Mu metal shielding are available to ensure data quality even under hostile conditions.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SynAmps RT 128-channel Amplifier</title>
		<link>https://compumedicsneuroscan.com/product/synamps-rt-128-channel-eeg-erp-ep-amplifier/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Tue, 25 Oct 2016 07:06:18 +0000</pubDate>
				<guid isPermaLink="false">http://compumedicsneuroscan.com/product/synamps-rt-128-channel-amplifier/</guid>

					<description><![CDATA[<strong>SynAmps RT</strong> is the one of the latest EEG, ERP and EP amplifier from Compumedics Neuroscan. Using the most current technology, the RT builds on the quality of the past SynAmps series of amplifiers and extends the specifications beyond anything that has come before.

<strong>SynAmps RT</strong> sets a new standard in amplifier technology, providing a system suitable for recording everything from high sampling rate (20,000 Hz) Auditory Brain Stem recordings and Spike Spindles to true DC recordings of CNV and P300.

The <strong>SynAmps RT</strong> also serves as the recommended platform for recording in the MRI and MEG, in conjunction with the <strong>Micro MagLink RT</strong> system. SynAmps RT includes clock synchronization circuitry, allowing the amplifier to synch with other devices, such as MR scanners, more precisely, without the need for very fast acquisition rates.

<strong>SynAmps RT</strong> can be used in conjunction with the <strong>CURRY</strong> software, providing a complete acquisition and analysis system, or with the ACCESS SDK, allowing user’s custom built software to control and acquire data from the system.

<strong>SynAmps RT</strong> can also be used with the <strong>STIM2</strong> system for integrated and accurate stimulus presentation or will accept TTL pulses from third party systems.

<strong>SynAmps RT</strong> can be used with the <strong>QuikCap</strong>, to provide fast and simple electrode placement or will accept any touch proof electrode as well. Grid, depth and microelectrodes may also be used with the SynAmps RT.

The <strong>SynAmps RT</strong> system has CE Class IIa medical certification and FDA approval.]]></description>
										<content:encoded><![CDATA[<p><strong>Channel Count Per Headbox: 64 Monopolar, 4 Bipolar, 2 High Level</strong><br />
Utilizing the latest technology, SynAmps RT allows for discrete monopolar and bipolar channels, enhancing the flexibility of recordings. Additional high level inputs are isolated to allow voltage level signals to be merged with the physiological data. Linking headboxes together allows more than 500 channels to be recorded.</p>
<p><span style="text-decoration: underline;">A 128-channel SynAmps RT EEG system consists of two headboxes, with 140 channels in total</span>.</p>
<p>A fully isolated, programmable bipolar excitation supply is also provided capable of supplying up to +/- 10VDC at 100mA to external bridges or measurement devices.</p>
<p><strong>Maximum Sampling Rate: 20,000 Per Channel all channels driven</strong><br />
Faster sampling rates allow for more accurate sampling of the analog data being recorded. Signals such as Auditory Brain Stem Response require these faster rates, while typical ERP measures benefit from increased resolution.</p>
<p><strong>Sampling Method: All Channels Sampled Simultaneously</strong><br />
Current technology eliminates the problems associated with sample and hold circuits. Utilizing a dedicated 24-bit A to D chip for each channel, the SynAmps RT enhances resolution and accuracy of each sample by ensuring a more valid measure of the data without decay or skew.</p>
<p>The 24-bit resolution allows for even the most subtle differences in amplitude to be measured accurately.</p>
<p><strong>Recording Bandwidth: DC to 3500 Hz</strong><br />
Many slow potentials (i.e., P300, MMN, CNV) have components that can only be measured accurately using a DC amplifier. DC amplifiers are also not subject to the AC coupled, filter time constant that distorts recordings after an artifact. The high frequency end of the SynAmps RT&#8217;s range allows for more accurate recording of the fastest frequencies.</p>
<p><strong>Active Noise Cancellation: Utilizing advanced driven reference technology</strong><br />
SynAmps RT sets a new standard for amplifier design, both in terms of safety and signal quality. Actively sampling environmental noise, and applying an antiphase signal to eliminate that noise, elevates the CMRR to unprecedented levels. This technology also provides increased patient protection.</p>
<p><strong>Recording in fMRI Environments: Integration with the Micro MagLink RT System</strong><br />
The same amplifier that is used in standard recording environments can also be used to record EEG data in the MRI by interfacing to the Micro MagLink RT system. SynAmps RT was built with enough input range and accuracy to sample both the EEG and the fMRI artifact with sufficient resolution to remove the artifact and ensure the EEG is left intact.</p>
<p><strong>&gt;10 G Ohm Input Impedance: Allows standard impedance or fast preparation to be obtained</strong><br />
SynAmps RT allows you to choose on a subject by subject basis to prepare the scalp electrode impedance to the scientifically accepted levels or to record with high impedance, due to time or subject constraints. This flexibility allows you the option to maximize your data collection for each subject and collect the best data the situation allows.</p>
<p><strong>Portability and Integration: Small Package, big features</strong><br />
Digital amplifiers are typically small and thus portable, but portability also means unpredictable environmental noise. SynAmps RT has built in technology to function even in the worst electromagnetic fields. Custom solutions such as Mu metal shielding are available to ensure data quality even under hostile conditions.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SynAmps RT 64-channel Amplifier</title>
		<link>https://compumedicsneuroscan.com/product/synamps-rt-64-channel-eeg-erp-ep-amplifier/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Mon, 24 Oct 2016 15:21:23 +0000</pubDate>
				<guid isPermaLink="false">http://compumedicsneuroscan.com/?post_type=product&#038;p=5269</guid>

					<description><![CDATA[<strong>SynAmps RT</strong> is the one of the latest EEG, ERP and EP amplifier from Compumedics Neuroscan. Using the most current technology, the RT builds on the quality of the past SynAmps series of amplifiers and extends the specifications beyond anything that has come before.

<strong>SynAmps RT</strong> sets a new standard in amplifier technology, providing a system suitable for recording everything from high sampling rate (20,000 Hz) Auditory Brain Stem recordings and Spike Spindles to true DC recordings of CNV and P300.

The <strong>SynAmps RT</strong> also serves as the recommended platform for recording in the MRI and MEG, in conjunction with the <strong>Micro MagLink RT</strong> system. SynAmps RT includes clock synchronization circuitry, allowing the amplifier to synch with other devices, such as MR scanners, more precisely, without the need for very fast acquisition rates.

<strong>SynAmps RT</strong> can be used in conjunction with the <strong>CURRY</strong> software, providing a complete acquisition and analysis system, or with the ACCESS SDK, allowing user’s custom built software to control and acquire data from the system.

<strong>SynAmps RT</strong> can also be used with the <strong>STIM2</strong> system for integrated and accurate stimulus presentation or will accept TTL pulses from third party systems.

<strong>SynAmps RT</strong> can be used with the <strong>QuikCap</strong>, to provide fast and simple electrode placement or will accept any touch proof electrode as well. Grid, depth and microelectrodes may also be used with the SynAmps RT.

The <strong>SynAmps RT</strong> system has CE Class IIa medical certification and FDA approval.]]></description>
										<content:encoded><![CDATA[<p><strong>Channel Count Per Headbox: 64 Monopolar, 4 Bipolar, 2 High Level</strong><br />
Utilizing the latest technology, SynAmps RT allows for discrete monopolar and bipolar channels, enhancing the flexibility of recordings. Additional high level inputs are isolated to allow voltage level signals to be merged with the physiological data. Linking headboxes together allows more than 500 channels to be recorded.</p>
<p><span style="text-decoration: underline;">A 64-channel SynAmps RT EEG system has one headbox, with 70 channels in total</span>.</p>
<p>A fully isolated, programmable bipolar excitation supply is also provided capable of supplying up to +/- 10VDC at 100mA to external bridges or measurement devices.</p>
<p><strong>Maximum Sampling Rate: 20,000 Per Channel all channels driven</strong><br />
Faster sampling rates allow for more accurate sampling of the analog data being recorded. Signals such as Auditory Brain Stem Response require these faster rates, while typical ERP measures benefit from increased resolution.</p>
<p><strong>Sampling Method: All Channels Sampled Simultaneously</strong><br />
Current technology eliminates the problems associated with sample and hold circuits. Utilizing a dedicated 24-bit A to D chip for each channel, the SynAmps RT enhances resolution and accuracy of each sample by ensuring a more valid measure of the data without decay or skew.</p>
<p>The 24-bit resolution allows for even the most subtle differences in amplitude to be measured accurately.</p>
<p><strong>Recording Bandwidth: DC to 3500 Hz</strong><br />
Many slow potentials (i.e., P300, MMN, CNV) have components that can only be measured accurately using a DC amplifier. DC amplifiers are also not subject to the AC coupled, filter time constant that distorts recordings after an artifact. The high frequency end of the SynAmps RT&#8217;s range allows for more accurate recording of the fastest frequencies.</p>
<p><strong>Active Noise Cancellation: Utilizing advanced driven reference technology</strong><br />
SynAmps RT sets a new standard for amplifier design, both in terms of safety and signal quality. Actively sampling environmental noise, and applying an antiphase signal to eliminate that noise, elevates the CMRR to unprecedented levels. This technology also provides increased patient protection.</p>
<p><strong>Recording in fMRI Environments: Integration with the Micro MagLink RT System</strong><br />
The same amplifier that is used in standard recording environments can also be used to record EEG data in the MRI by interfacing to the Micro MagLink RT system. SynAmps RT was built with enough input range and accuracy to sample both the EEG and the fMRI artifact with sufficient resolution to remove the artifact and ensure the EEG is left intact.</p>
<p><strong>&gt;10 G Ohm Input Impedance: Allows standard impedance or fast preparation to be obtained</strong><br />
SynAmps RT allows you to choose on a subject by subject basis to prepare the scalp electrode impedance to the scientifically accepted levels or to record with high impedance, due to time or subject constraints. This flexibility allows you the option to maximize your data collection for each subject and collect the best data the situation allows.</p>
<p><strong>Portability and Integration: Small Package, big features</strong><br />
Digital amplifiers are typically small and thus portable, but portability also means unpredictable environmental noise. SynAmps RT has built in technology to function even in the worst electromagnetic fields. Custom solutions such as Mu metal shielding are available to ensure data quality even under hostile conditions.</p>