<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Research EEG &#8211; Compumedics Neuroscan</title>
	<atom:link href="https://compumedicsneuroscan.com/applications/research-eeg/feed/" rel="self" type="application/rss+xml" />
	<link>https://compumedicsneuroscan.com</link>
	<description>World Leader in Functional Neuro-imaging</description>
	<lastBuildDate>Thu, 10 Apr 2025 09:56:16 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	
	<item>
		<title>Grael LT EEG Amplifier</title>
		<link>https://compumedicsneuroscan.com/product/grael-lt-eeg-amplifier/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Thu, 27 Oct 2016 09:31:24 +0000</pubDate>
				<guid isPermaLink="false">http://compumedicsneuroscan.com/product/grael-lt-eeg-amplifier/</guid>

					<description><![CDATA[The <strong>Grael LT</strong> amplifier is a cost-efficient amplifier aimed at running either clinical EEG or basic research EEG studies.

A single IP connection to the Grael amplifier provides both power and data transmission, making it very easy to set up the system at different locations in your department.

The <strong>Grael LT</strong> system has CE Class IIa medical certification and FDA approval.]]></description>
										<content:encoded><![CDATA[<p>Over 25 years of experience in designing EEG and PSG amplifiers has culminated in the new <strong>Grael</strong> amplifier range – Compumedics’ most technologically advanced amplifier yet. Four new amplifiers specifically designed to fit your needs! The <strong>Grael LT</strong> Amplifier is the most cost-efficient of them, especially suited for running EEG, for both clinical and basic research applications.</p>
<h3>Key features</h3>
<ul>
<li>Optimzed for clinical EEG and basic research</li>
<li>Sampling Rates up to 2048 Hz</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Grael 4K EEG Amplifier</title>
		<link>https://compumedicsneuroscan.com/product/grael-4k-eeg-amplifier/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Thu, 27 Oct 2016 09:01:15 +0000</pubDate>
				<guid isPermaLink="false">http://compumedicsneuroscan.com/product/grael-4k-eeg-amplifier/</guid>

					<description><![CDATA[The <strong>Grael 4K EEG</strong> amplifier is a powerful evolution of the first version of the Grael amplifier. The amplifier is well suited for EEG studies in both research and clinical applications. Whether you are interested in EEG or evoked potentials, or wish to run longterm epilepsy monitoring studies (LTM) or ICU studies, the <strong>Grael 4K EEG</strong> amplifier will be your choice. Multiple devices can even be combined for running group studies.

A single IP connection to the Grael amplifier provides both power and data transmission, making it very easy to set up the system at different locations in your department.

The <strong>Grael 4K EEG</strong> system has CE Class IIa medical certification and FDA approval.]]></description>
										<content:encoded><![CDATA[<p>Over 25 years of experience in designing EEG and PSG amplifiers has culminated in the new <strong>Grael</strong> amplifier range – Compumedics’ most technologically advanced amplifier yet. Four new amplifiers specifically designed to fit your needs! The Grael 4K EEG Amplifier is the most advanced amplifier of them, especially suited for running EEG and evoked potentials, for both clinical and research applications.</p>
<h3>Key features</h3>
<ul>
<li>Advanced EEG signal acquisition for research and clinical applications</li>
<li>LTM, Routine, ICU and Evoked Potentials</li>
<li>Sampling Rates up to 4096 Hz</li>
<li>User selectable gain allows choice of lower noise or higher allowable DC offset (great for combining EEG with TDCS/TACS or TMS)</li>
<li>Combine multiple devices for more channels or group studies (hyperscanning)</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Grael PSG Amplifier</title>
		<link>https://compumedicsneuroscan.com/product/grael-psg-amplifier/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Thu, 27 Oct 2016 08:19:47 +0000</pubDate>
				<guid isPermaLink="false">http://compumedicsneuroscan.com/product/grael-4k-psg-amplifier/</guid>

					<description><![CDATA[Over 25 years of experience in designing PSG and EEG amplifiers, including the highly successful E-Series, has culminated in <strong>Grael PSG</strong>. Based on the flagship Grael amplifier, the <strong>Grael PSG</strong> has a channel subset dedicated for Sleep studies. A true-HD PSG amplifier with channels as specified for the Gold standard AASM Type 1 studies.

A single IP connection to the Grael amplifier provides both power and data transmission, making it very easy to set up the system at different locations in your department.

The <strong>Grael</strong> system has CE Class IIa medical certification and FDA approval.]]></description>
										<content:encoded><![CDATA[<p>Industry-leading amplifier optimized for Gold Standard HD PSG studies.</p>
<h3>Key features</h3>
<ul>
<li>Optimized for sleep studies</li>
<li>Supports a great selection of sleep sensors including an integrated light sensor</li>
<li>DC Amplifier with sampling rates up to 2048 Hz</li>
<li>True high definition (HD) signal quality</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Grael 4K PSG:EEG Amplifier</title>
		<link>https://compumedicsneuroscan.com/product/grael-4k-psg-eeg-erp-amplifier/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Thu, 27 Oct 2016 06:15:06 +0000</pubDate>
				<guid isPermaLink="false">http://compumedicsneuroscan.com/product/grael-4k-psgeeg/</guid>

					<description><![CDATA[The <strong>Grael 4K</strong> is the most advanced amplifier on the market today. Compumedics’ flagship, high-definition EEG, sleep and research amplifier specified for the most demanding cognitive research or epilepsy/sleep diagnostics. Experience the new and more powerful Grael.

A single IP connection to the Grael amplifier provides both power and data transmission, making it very easy to set up the system at different locations in your department.

The <strong>Grael 4K</strong> system has CE Class IIa medical certification and FDA approval.]]></description>
										<content:encoded><![CDATA[<p>Over 25 years of experience in designing EEG and PSG amplifiers has culminated in the new <strong>Grael</strong> amplifier range – Compumedics’ most technologically advanced amplifier yet. Four new amplifiers specifically designed to fit your needs! The Grael 4K PSG:EEG Amplifier is the most advanced amplifier of them.</p>
<h3>Key features</h3>
<ul>
<li>Amplifier can be used for wide range of applications including EEG, Evoked Potentials (ERP) and Sleep studies</li>
<li>Sampling Rates up to 4096 Hz</li>
<li>User selectable gain allows choice of lower noise or higher allowable DC offset (great for combining EEG with TDCS/TACS or TMS)</li>
<li>Combine multiple devices for more channels or group studies (hyperscanning)</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Siesta Wireless EEG Amplifier</title>
		<link>https://compumedicsneuroscan.com/product/siesta-wireless-eeg-amplifier/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Wed, 26 Oct 2016 16:58:40 +0000</pubDate>
				<guid isPermaLink="false">http://compumedicsneuroscan.com/product/siesta-wireless-eeg-amplifier/</guid>

					<description><![CDATA[&#160;
<p class="">The <strong>Siesta</strong> 32-channel EEG amplifier is <span style="text-decoration: underline;">the</span> solution for wireless EEG recordings. Imagine having the freedom for your subject to move and still being able record clean EEG data. The <strong>Siesta</strong> amplifier gives you this flexibility. With a weight of only 300 grams (9.6 ounces, including battery) and a revolutionary small size, the system is very suitable for sports medicine, rehabilitation research and related applications where mobility is important.</p>
The secure WIFI data transmission allow you to collect data while your subject is mobile. In case the connection to the WIFI is lost the onboard storage makes sure you do not loose any valuable data.

Multiple Siesta devices may be used within the same network/room and gives you the opportunity to perform multi-subject recordings and monitor interactions within a group. Doing research has never been so exciting.

The <strong>Siesta</strong> system has CE Class IIa medical certification and FDA approval.]]></description>
										<content:encoded><![CDATA[<h3>Revolutionary Flexibility</h3>
<p>The Siesta amplifier provides 32 channels for data collection: any physiological signal may be recorded on any channel:</p>
<ul>
<li>Differential or Referential</li>
<li>True 16 bit resolution</li>
<li>Sampling rates to 1024Hz</li>
<li>Two expansion ports for accessory modules; oximeter, pressure transducers, event button….interface up to 32 additional signals</li>
</ul>
<h3>Revolutionary Power</h3>
<ul>
<li>Use standard alkaline A cells…OR</li>
<li>Use rechargeable NiMH battery pack (Recharger built in – recharge Siesta just like you charge your cell phone)…OR</li>
<li>Run Siesta on AC power; just plug it in</li>
</ul>
<h3>Revolutionary Wireless Data Transmission</h3>
<p>Siesta’s ethernet radio link provides the researcher with testing options and opportunities never before available. Your subjects are free to move about while you continue to monitor and collect data. Set up a testing room in just minutes. Use Siesta in your movement lab or as your best solution for recording outdoor. The Siesta802a is compatible with all current 802.11 wireless network standards, including the 2.4GHz and 5 GHz bands.With proper configuration, the Siesta System works with most wireless network infrastructures commonly in place in hospitals. Compumedics also provides a line of Access Point Modules. The Siesta System supports WEP (40 and 128-bit), WPA1-PSK and WPA2-PSK security standards.</p>
<h3>Revolutionary Data Storage</h3>
<ul>
<li>Record directly to the on-board, industry standard Compact Flash Card (various sizes available) OR</li>
<li>Record all raw data directly to the computer over wireless network link…error free OR</li>
<li>Both simultaneously (Instant Backup)</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Neuvo 256-channel Amplifier</title>
		<link>https://compumedicsneuroscan.com/product/neuvo-256-channel-eeg-erp-ep-amplifier/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Wed, 26 Oct 2016 14:18:01 +0000</pubDate>
				<guid isPermaLink="false">http://compumedicsneuroscan.com/product/neuvo-256-channel-amplifier/</guid>

					<description><![CDATA[The <strong>Neuvo</strong> is well suited to meet the needs of any Neuroscience laboratory. Build on the technology of the SynAmps RT, the Neuvo is an EEG, ERP and EP amplifier with very high specifications at a competitive price.

<strong>Neuvo</strong> sets a new standard in amplifier technology, providing a system suitable for recording everything from high sampling rate (10,000 Hz) Auditory Brain Stem recordings and Spike Spindles to true DC recordings of CNV and P300.

The <strong>Neuvo</strong> can be used in conjunction with the <strong>CURRY</strong> software, providing a complete acquisition and analysis system, or with the ACCESS SDK, allowing user’s custom built software to control and acquire data from the system.

<strong>Neuvo</strong> can also be used with the <strong>STIM2</strong> system for integrated and accurate stimulus presentation or will accept TTL pulses from third party systems.

<strong>Neuvo</strong> can be used with the <strong>QuikCap</strong>, to provide fast and simple electrode placement or will accept any touch proof electrode as well. Grid, depth and microelectrodes may also be used with the Neuvo.

The <strong>Neuvo</strong> system has CE Class IIa medical certification and FDA approval.]]></description>
										<content:encoded><![CDATA[<p><strong>Channel Count Per Headbox: 64 Monopolar and 4 Bipolar</strong><br />
Utilizing the latest technology, Neuvo allows for discrete monopolar and bipolar channels, enhancing the flexibility of recordings. Linking headboxes together allows more than 500 channels to be recorded.</p>
<p><span style="text-decoration: underline;">A 256-channel Neuvo EEG system has four headboxes, with 272 channels in total</span>.</p>
<p><strong>Maximum Sampling Rate: 10,000 Per Channel all channels driven</strong><br />
Faster sampling rates allow for more accurate sampling of the analog data being recorded. Signals such as Auditory Brain Stem Response require these faster rates, while typical ERP measures benefit from increased resolution.</p>
<p><strong>Sampling Method: All Channels Sampled Simultaneously</strong><br />
Current technology eliminates the problems associated with sample and hold circuits. Utilizing a dedicated 24-bit A to D chip for each channel, the Neuvo enhances resolution and accuracy of each sample by ensuring a more valid measure of the data without decay or skew.</p>
<p>The 24-bit resolution allows for even the most subtle differences in amplitude to be measured accurately.</p>
<p><strong>Recording Bandwidth: DC to 3500 Hz</strong><br />
Many slow potentials (i.e., P300, MMN, CNV) have components that can only be measured accurately using a DC amplifier. DC amplifiers are also not subject to the AC coupled, filter time constant that distorts recordings after an artifact. The high frequency end of the Neuvo&#8217;s range allows for more accurate recording of the fastest frequencies.</p>
<p><strong>Active Noise Cancellation: Utilizing advanced driven reference technology</strong><br />
Neuvo sets a new standard for amplifier design, both in terms of safety and signal quality. Actively sampling environmental noise, and applying an antiphase signal to eliminate that noise, elevates the CMRR to unprecedented levels. This technology also provides increased patient protection.</p>
<p><strong>&gt;10 G Ohm Input Impedance: Allows standard impedance or fast preparation to be obtained</strong><br />
Neuvo allows you to choose on a subject by subject basis to prepare the scalp electrode impedance to the scientifically accepted levels or to record with high impedance, due to time or bject constraints. This flexibility allows you the option to maximize your data collection for each subject and collect the best data the situation allows.</p>
<p><strong>Portability and Integration: Small Package, big features</strong><br />
Digital amplifiers are typically small and thus portable, but portability also means unpredictable environmental noise. Neuvo has built in technology to function even in the worst electromagnetic fields.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Neuvo 128-channel Amplifier</title>
		<link>https://compumedicsneuroscan.com/product/neuvo-128-channel-eeg-erp-ep-amplifier/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Wed, 26 Oct 2016 14:07:26 +0000</pubDate>
				<guid isPermaLink="false">http://compumedicsneuroscan.com/product/neuvo-128-channel-amplifier/</guid>

					<description><![CDATA[The <strong>Neuvo</strong> is well suited to meet the needs of any Neuroscience laboratory. Build on the technology of the SynAmps RT, the Neuvo is an EEG, ERP and EP amplifier with very high specifications at a competitive price.

<strong>Neuvo</strong> sets a new standard in amplifier technology, providing a system suitable for recording everything from high sampling rate (10,000 Hz) Auditory Brain Stem recordings and Spike Spindles to true DC recordings of CNV and P300.

The <strong>Neuvo</strong> can be used in conjunction with the <strong>CURRY</strong> software, providing a complete acquisition and analysis system, or with the ACCESS SDK, allowing user’s custom built software to control and acquire data from the system.

<strong>Neuvo</strong> can also be used with the <strong>STIM2</strong> system for integrated and accurate stimulus presentation or will accept TTL pulses from third party systems.

<strong>Neuvo</strong> can be used with the <strong>QuikCap</strong>, to provide fast and simple electrode placement or will accept any touch proof electrode as well. Grid, depth and microelectrodes may also be used with the Neuvo.

The <strong>Neuvo</strong> system has CE Class IIa medical certification and FDA approval.]]></description>
										<content:encoded><![CDATA[<p><strong>Channel Count Per Headbox: 64 Monopolar and 4 Bipolar</strong><br />
Utilizing the latest technology, Neuvo allows for discrete monopolar and bipolar channels, enhancing the flexibility of recordings. Linking headboxes together allows more than 500 channels to be recorded.</p>
<p><span style="text-decoration: underline;">A 128-channel Neuvo EEG system has two headboxes, with 136 channels in total</span>.</p>
<p><strong>Maximum Sampling Rate: 10,000 Per Channel all channels driven</strong><br />
Faster sampling rates allow for more accurate sampling of the analog data being recorded. Signals such as Auditory Brain Stem Response require these faster rates, while typical ERP measures benefit from increased resolution.</p>
<p><strong>Sampling Method: All Channels Sampled Simultaneously</strong><br />
Current technology eliminates the problems associated with sample and hold circuits. Utilizing a dedicated 24-bit A to D chip for each channel, the Neuvo enhances resolution and accuracy of each sample by ensuring a more valid measure of the data without decay or skew.</p>
<p>The 24-bit resolution allows for even the most subtle differences in amplitude to be measured accurately.</p>
<p><strong>Recording Bandwidth: DC to 3500 Hz</strong><br />
Many slow potentials (i.e., P300, MMN, CNV) have components that can only be measured accurately using a DC amplifier. DC amplifiers are also not subject to the AC coupled, filter time constant that distorts recordings after an artifact. The high frequency end of the Neuvo&#8217;s range allows for more accurate recording of the fastest frequencies.</p>
<p><strong>Active Noise Cancellation: Utilizing advanced driven reference technology</strong><br />
Neuvo sets a new standard for amplifier design, both in terms of safety and signal quality. Actively sampling environmental noise, and applying an antiphase signal to eliminate that noise, elevates the CMRR to unprecedented levels. This technology also provides increased patient protection.</p>
<p><strong>&gt;10 G Ohm Input Impedance: Allows standard impedance or fast preparation to be obtained</strong><br />
Neuvo allows you to choose on a subject by subject basis to prepare the scalp electrode impedance to the scientifically accepted levels or to record with high impedance, due to time or bject constraints. This flexibility allows you the option to maximize your data collection for each subject and collect the best data the situation allows.</p>
<p><strong>Portability and Integration: Small Package, big features</strong><br />
Digital amplifiers are typically small and thus portable, but portability also means unpredictable environmental noise. Neuvo has built in technology to function even in the worst electromagnetic fields.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Neuvo 64-channel Amplifier</title>
		<link>https://compumedicsneuroscan.com/product/neuvo-64-channel-eeg-erp-ep-amplifier/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Wed, 26 Oct 2016 13:43:49 +0000</pubDate>
				<guid isPermaLink="false">http://compumedicsneuroscan.com/product/neuvo-64-channel-amplifier/</guid>

					<description><![CDATA[The <strong>Neuvo</strong> is well suited to meet the needs of any Neuroscience laboratory. Build on the technology of the SynAmps RT, the Neuvo is an EEG, ERP and EP amplifier with very high specifications at a competitive price.

<strong>Neuvo</strong> sets a new standard in amplifier technology, providing a system suitable for recording everything from high sampling rate (10,000 Hz) Auditory Brain Stem recordings and Spike Spindles to true DC recordings of CNV and P300.

The <strong>Neuvo</strong> can be used in conjunction with the <strong>CURRY</strong> software, providing a complete acquisition and analysis system, or with the ACCESS SDK, allowing user’s custom built software to control and acquire data from the system.

<strong>Neuvo</strong> can also be used with the <strong>STIM2</strong> system for integrated and accurate stimulus presentation or will accept TTL pulses from third party systems.

<strong>Neuvo</strong> can be used with the <strong>QuikCap</strong>, to provide fast and simple electrode placement or will accept any touch proof electrode as well. Grid, depth and microelectrodes may also be used with the Neuvo.

The <strong>Neuvo</strong> system has CE Class IIa medical certification and FDA approval.]]></description>
										<content:encoded><![CDATA[<p><strong>Channel Count Per Headbox: 64 Monopolar and 4 Bipolar</strong><br />
Utilizing the latest technology, Neuvo allows for discrete monopolar and bipolar channels, enhancing the flexibility of recordings. Linking headboxes together allows more than 500 channels to be recorded.</p>
<p><span style="text-decoration: underline;">A 64-channel Neuvo EEG system has one headbox, with 68 channels in total</span>.</p>
<p><strong>Maximum Sampling Rate: 10,000 Per Channel all channels driven</strong><br />
Faster sampling rates allow for more accurate sampling of the analog data being recorded. Signals such as Auditory Brain Stem Response require these faster rates, while typical ERP measures benefit from increased resolution.</p>
<p><strong>Sampling Method: All Channels Sampled Simultaneously</strong><br />
Current technology eliminates the problems associated with sample and hold circuits. Utilizing a dedicated 24-bit A to D chip for each channel, the Neuvo enhances resolution and accuracy of each sample by ensuring a more valid measure of the data without decay or skew.</p>
<p>The 24-bit resolution allows for even the most subtle differences in amplitude to be measured accurately.</p>
<p><strong>Recording Bandwidth: DC to 3500 Hz</strong><br />
Many slow potentials (i.e., P300, MMN, CNV) have components that can only be measured accurately using a DC amplifier. DC amplifiers are also not subject to the AC coupled, filter time constant that distorts recordings after an artifact. The high frequency end of the Neuvo&#8217;s range allows for more accurate recording of the fastest frequencies.</p>
<p><strong>Active Noise Cancellation: Utilizing advanced driven reference technology</strong><br />
Neuvo sets a new standard for amplifier design, both in terms of safety and signal quality. Actively sampling environmental noise, and applying an antiphase signal to eliminate that noise, elevates the CMRR to unprecedented levels. This technology also provides increased patient protection.</p>
<p><strong>&gt;10 G Ohm Input Impedance: Allows standard impedance or fast preparation to be obtained</strong><br />
Neuvo allows you to choose on a subject by subject basis to prepare the scalp electrode impedance to the scientifically accepted levels or to record with high impedance, due to time or bject constraints. This flexibility allows you the option to maximize your data collection for each subject and collect the best data the situation allows.</p>
<p><strong>Portability and Integration: Small Package, big features</strong><br />
Digital amplifiers are typically small and thus portable, but portability also means unpredictable environmental noise. Neuvo has built in technology to function even in the worst electromagnetic fields.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SynAmps RT 256-channel Amplifier</title>
		<link>https://compumedicsneuroscan.com/product/synamps-rt-256-channel-eeg-erp-ep-amplifier/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Tue, 25 Oct 2016 07:13:00 +0000</pubDate>
				<guid isPermaLink="false">http://compumedicsneuroscan.com/product/synamps-rt-256-channel-amplifier/</guid>

					<description><![CDATA[<strong>SynAmps RT</strong> is the one of the latest EEG, ERP and EP amplifier from Compumedics Neuroscan. Using the most current technology, the RT builds on the quality of the past SynAmps series of amplifiers and extends the specifications beyond anything that has come before.

<strong>SynAmps RT</strong> sets a new standard in amplifier technology, providing a system suitable for recording everything from high sampling rate (20,000 Hz) Auditory Brain Stem recordings and Spike Spindles to true DC recordings of CNV and P300.

The <strong>SynAmps RT</strong> also serves as the recommended platform for recording in the MRI and MEG, in conjunction with the <strong>Micro MagLink RT</strong> system. SynAmps RT includes clock synchronization circuitry, allowing the amplifier to synch with other devices, such as MR scanners, more precisely, without the need for very fast acquisition rates.

<strong>SynAmps RT</strong> can be used in conjunction with the <strong>CURRY</strong> software, providing a complete acquisition and analysis system, or with the ACCESS SDK, allowing user’s custom built software to control and acquire data from the system.

<strong>SynAmps RT</strong> can also be used with the <strong>STIM2</strong> system for integrated and accurate stimulus presentation or will accept TTL pulses from third party systems.

<strong>SynAmps RT</strong> can be used with the <strong>QuikCap</strong>, to provide fast and simple electrode placement or will accept any touch proof electrode as well. Grid, depth and microelectrodes may also be used with the SynAmps RT.

The <strong>SynAmps RT</strong> system has CE Class IIa medical certification and FDA approval.]]></description>
										<content:encoded><![CDATA[<p><strong>Channel Count Per Headbox: 64 Monopolar, 4 Bipolar, 2 High Level</strong><br />
Utilizing the latest technology, SynAmps RT allows for discrete monopolar and bipolar channels, enhancing the flexibility of recordings. Additional high level inputs are isolated to allow voltage level signals to be merged with the physiological data. Linking headboxes together allows more than 500 channels to be recorded.</p>
<p><span style="text-decoration: underline;">A 256-channel SynAmps RT EEG system consists of four headboxes, with 280 channels in total</span>.</p>
<p>A fully isolated, programmable bipolar excitation supply is also provided capable of supplying up to +/- 10VDC at 100mA to external bridges or measurement devices.</p>
<p><strong>Maximum Sampling Rate: 20,000 Per Channel all channels driven</strong><br />
Faster sampling rates allow for more accurate sampling of the analog data being recorded. Signals such as Auditory Brain Stem Response require these faster rates, while typical ERP measures benefit from increased resolution.</p>
<p><strong>Sampling Method: All Channels Sampled Simultaneously</strong><br />
Current technology eliminates the problems associated with sample and hold circuits. Utilizing a dedicated 24-bit A to D chip for each channel, the SynAmps RT enhances resolution and accuracy of each sample by ensuring a more valid measure of the data without decay or skew.</p>
<p>The 24-bit resolution allows for even the most subtle differences in amplitude to be measured accurately.</p>
<p><strong>Recording Bandwidth: DC to 3500 Hz</strong><br />
Many slow potentials (i.e., P300, MMN, CNV) have components that can only be measured accurately using a DC amplifier. DC amplifiers are also not subject to the AC coupled, filter time constant that distorts recordings after an artifact. The high frequency end of the SynAmps RT&#8217;s range allows for more accurate recording of the fastest frequencies.</p>
<p><strong>Active Noise Cancellation: Utilizing advanced driven reference technology</strong><br />
SynAmps RT sets a new standard for amplifier design, both in terms of safety and signal quality. Actively sampling environmental noise, and applying an antiphase signal to eliminate that noise, elevates the CMRR to unprecedented levels. This technology also provides increased patient protection.</p>
<p><strong>Recording in fMRI Environments: Integration with the Micro MagLink RT System</strong><br />
The same amplifier that is used in standard recording environments can also be used to record EEG data in the MRI by interfacing to the Micro MagLink RT system. SynAmps RT was built with enough input range and accuracy to sample both the EEG and the fMRI artifact with sufficient resolution to remove the artifact and ensure the EEG is left intact.</p>
<p><strong>&gt;10 G Ohm Input Impedance: Allows standard impedance or fast preparation to be obtained</strong><br />
SynAmps RT allows you to choose on a subject by subject basis to prepare the scalp electrode impedance to the scientifically accepted levels or to record with high impedance, due to time or subject constraints. This flexibility allows you the option to maximize your data collection for each subject and collect the best data the situation allows.</p>
<p><strong>Portability and Integration: Small Package, big features</strong><br />
Digital amplifiers are typically small and thus portable, but portability also means unpredictable environmental noise. SynAmps RT has built in technology to function even in the worst electromagnetic fields. Custom solutions such as Mu metal shielding are available to ensure data quality even under hostile conditions.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SynAmps RT 128-channel Amplifier</title>
		<link>https://compumedicsneuroscan.com/product/synamps-rt-128-channel-eeg-erp-ep-amplifier/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Tue, 25 Oct 2016 07:06:18 +0000</pubDate>
				<guid isPermaLink="false">http://compumedicsneuroscan.com/product/synamps-rt-128-channel-amplifier/</guid>

					<description><![CDATA[<strong>SynAmps RT</strong> is the one of the latest EEG, ERP and EP amplifier from Compumedics Neuroscan. Using the most current technology, the RT builds on the quality of the past SynAmps series of amplifiers and extends the specifications beyond anything that has come before.

<strong>SynAmps RT</strong> sets a new standard in amplifier technology, providing a system suitable for recording everything from high sampling rate (20,000 Hz) Auditory Brain Stem recordings and Spike Spindles to true DC recordings of CNV and P300.

The <strong>SynAmps RT</strong> also serves as the recommended platform for recording in the MRI and MEG, in conjunction with the <strong>Micro MagLink RT</strong> system. SynAmps RT includes clock synchronization circuitry, allowing the amplifier to synch with other devices, such as MR scanners, more precisely, without the need for very fast acquisition rates.

<strong>SynAmps RT</strong> can be used in conjunction with the <strong>CURRY</strong> software, providing a complete acquisition and analysis system, or with the ACCESS SDK, allowing user’s custom built software to control and acquire data from the system.

<strong>SynAmps RT</strong> can also be used with the <strong>STIM2</strong> system for integrated and accurate stimulus presentation or will accept TTL pulses from third party systems.

<strong>SynAmps RT</strong> can be used with the <strong>QuikCap</strong>, to provide fast and simple electrode placement or will accept any touch proof electrode as well. Grid, depth and microelectrodes may also be used with the SynAmps RT.

The <strong>SynAmps RT</strong> system has CE Class IIa medical certification and FDA approval.]]></description>
										<content:encoded><![CDATA[<p><strong>Channel Count Per Headbox: 64 Monopolar, 4 Bipolar, 2 High Level</strong><br />
Utilizing the latest technology, SynAmps RT allows for discrete monopolar and bipolar channels, enhancing the flexibility of recordings. Additional high level inputs are isolated to allow voltage level signals to be merged with the physiological data. Linking headboxes together allows more than 500 channels to be recorded.</p>
<p><span style="text-decoration: underline;">A 128-channel SynAmps RT EEG system consists of two headboxes, with 140 channels in total</span>.</p>
<p>A fully isolated, programmable bipolar excitation supply is also provided capable of supplying up to +/- 10VDC at 100mA to external bridges or measurement devices.</p>
<p><strong>Maximum Sampling Rate: 20,000 Per Channel all channels driven</strong><br />
Faster sampling rates allow for more accurate sampling of the analog data being recorded. Signals such as Auditory Brain Stem Response require these faster rates, while typical ERP measures benefit from increased resolution.</p>
<p><strong>Sampling Method: All Channels Sampled Simultaneously</strong><br />
Current technology eliminates the problems associated with sample and hold circuits. Utilizing a dedicated 24-bit A to D chip for each channel, the SynAmps RT enhances resolution and accuracy of each sample by ensuring a more valid measure of the data without decay or skew.</p>
<p>The 24-bit resolution allows for even the most subtle differences in amplitude to be measured accurately.</p>
<p><strong>Recording Bandwidth: DC to 3500 Hz</strong><br />
Many slow potentials (i.e., P300, MMN, CNV) have components that can only be measured accurately using a DC amplifier. DC amplifiers are also not subject to the AC coupled, filter time constant that distorts recordings after an artifact. The high frequency end of the SynAmps RT&#8217;s range allows for more accurate recording of the fastest frequencies.</p>
<p><strong>Active Noise Cancellation: Utilizing advanced driven reference technology</strong><br />
SynAmps RT sets a new standard for amplifier design, both in terms of safety and signal quality. Actively sampling environmental noise, and applying an antiphase signal to eliminate that noise, elevates the CMRR to unprecedented levels. This technology also provides increased patient protection.</p>
<p><strong>Recording in fMRI Environments: Integration with the Micro MagLink RT System</strong><br />
The same amplifier that is used in standard recording environments can also be used to record EEG data in the MRI by interfacing to the Micro MagLink RT system. SynAmps RT was built with enough input range and accuracy to sample both the EEG and the fMRI artifact with sufficient resolution to remove the artifact and ensure the EEG is left intact.</p>
<p><strong>&gt;10 G Ohm Input Impedance: Allows standard impedance or fast preparation to be obtained</strong><br />
SynAmps RT allows you to choose on a subject by subject basis to prepare the scalp electrode impedance to the scientifically accepted levels or to record with high impedance, due to time or subject constraints. This flexibility allows you the option to maximize your data collection for each subject and collect the best data the situation allows.</p>
<p><strong>Portability and Integration: Small Package, big features</strong><br />
Digital amplifiers are typically small and thus portable, but portability also means unpredictable environmental noise. SynAmps RT has built in technology to function even in the worst electromagnetic fields. Custom solutions such as Mu metal shielding are available to ensure data quality even under hostile conditions.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
