<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Products &#8211; Compumedics Neuroscan</title>
	<atom:link href="https://compumedicsneuroscan.com/products/feed/" rel="self" type="application/rss+xml" />
	<link>https://compumedicsneuroscan.com</link>
	<description>World Leader in Functional Neuro-imaging</description>
	<lastBuildDate>Wed, 17 May 2023 08:51:26 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	
	<item>
		<title>CURRY 9 SBA &#8211; Signal Processing, Advanced Image Processing and Source Analysis</title>
		<link>https://compumedicsneuroscan.com/product/curry-9-sba-signal-processing-advanced-image-processing-and-source-analysis/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Fri, 07 Jan 2022 12:43:34 +0000</pubDate>
				<guid isPermaLink="false">https://compumedicsneuroscan.com/?post_type=product&#038;p=7546</guid>

					<description><![CDATA[CURRY 9 Signal Processing, Advanced Image Processing and Source Analysis (SBA)]]></description>
										<content:encoded><![CDATA[<p>The CURRY 9 Signal Processing, Advanced Image Processing and Source Analysis (SBA) Package is the most complete package of CURRY 9 for analysis of your EEG and MEG data. The only modules missing in this version of CURRY 9, are the EEG Data Acquisition and Digitizer Control. Those modules are available as add-ons to the CURRY 9 SBA Package.</p>
<p>In addition to the features described for the Signal Processing package of CURRY, this package also features:</p>
<ul>
<li>Integration of EEG, MEG, ECoG, ECG, MCG, with MRI, fMRI, CT, PET, SPECT</li>
<li>Complete data processing from filtering to source analysis</li>
<li>Event support, template-based event detection</li>
<li>Principal and Independent Component Analysis (PCA, ICA) and filtering</li>
<li>Individual realistic head models using the Boundary Element Method (BEM) and Finite Element Method (FEM)</li>
<li>Pre-computed BEM and Finite Element Method (FEM) head models</li>
<li>Dipole fits – Dipole confidence ellipsoids are computed</li>
<li>Dipole clustering</li>
<li>Dipole scans, extended source (patch) scans, and MUSIC scans</li>
<li>Beamforming based on dipolar or extended sources</li>
<li>Current density analysis, extended sources, Lp norms, sLORETA, eLORETA, swLORETA, SWARM, FOCUSS, LAURA, ssLOFO</li>
<li>Sensor Coherence and Source Coherence Analysis</li>
</ul>
<p><a href="https://compumedicsneuroscan.com/wp-content/uploads/CURRY-Package-Information-Card-2023.pdf">CURRY Package Information Card</a></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>CURRY 9 I &#8211; Advanced Image Processing</title>
		<link>https://compumedicsneuroscan.com/product/curry-9-i-advanced-image-processing/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Fri, 07 Jan 2022 12:39:52 +0000</pubDate>
				<guid isPermaLink="false">https://compumedicsneuroscan.com/?post_type=product&#038;p=7545</guid>

					<description><![CDATA[CURRY 9 Advanced Image Processing (I)]]></description>
										<content:encoded><![CDATA[<p>The Image Processing Package of CURRY 9 has been designed especially for those users that work primarily with image data. The package offers a set powerful tools for processing medical 3D image data. Images from two or three modalities can be used simultaneously. Automatic co-registration, segmentation, morphological operations, and meshing are available.</p>
<p><a href="https://compumedicsneuroscan.com/wp-content/uploads/CURRY-Package-Information-Card-2023.pdf">CURRY Package Information Card</a></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>CURRY 9 X &#8211; Data Acquisition and Online Processing</title>
		<link>https://compumedicsneuroscan.com/product/curry-9-x-data-acquisition-and-online-processing/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Thu, 23 Dec 2021 15:45:10 +0000</pubDate>
				<guid isPermaLink="false">https://compumedicsneuroscan.com/?post_type=product&#038;p=7503</guid>

					<description><![CDATA[The CURRY 9 X Data Acquisition package is an easy-to-use and reliable tool for EEG data recording and online processing. All the features required for data acquisition are supported; for instance impedance check, online filtering, real-time event averaging, real-time fMRI/TMS artefact correction and many more. Using the TCP/IP interface, data is immediately available to other packages (for instance Matlab) and allows for BCI applications.

CURRY data files are fully compatible with EEGLAB.]]></description>
										<content:encoded><![CDATA[<p>The CURRY Neuroimaging Suite software is divided into several modules that can stand alone or work together to maximize your lab’s flexibility. The Acquire and Online Signal Processing package consists of all primary features and functions needed for acquiring high-quality EEG/EP/ERP data and online/real-time processing.</p>
<p>Acquisition in CURRY is enhanced with easier, more flexible, and more advanced tools for on-line data processing, with up to 512 channels and sampling rates up to 20 kHz.</p>
<p>CURRY will support EEG data acquisition with <a href="/products/by-name/synamps-2-rt/">SynAmps 2/RT</a>, <a href="http://compumedicsneuroscan.com/product/siesta-wireless-eeg-amplifier/">Siesta</a>, NuAmps, <a href="/products/by-name/neuvo/">Neuvo</a>, <a href="/products/by-name/grael/">Grael</a>, and E-Series <a href="/products/amplifiers/">amplifiers</a>. Each amplifier has its own set-up image to ensure ease of use in setting the system.</p>
<p>Online Artifact Reduction for up to five types of artifact can be applied simultaneously, letting you verify the quality of the data while the subject is still connected. Artifacts include blinks, pulse artifact, MR gradient artifact, ballistocardiogram, and bad blocks. Reduction methods include Subtraction, Covariance, PCA, and ICA.</p>
<p>On-line averaging is enhanced, with the ability to extract both standard TTL triggered and conditional averages. Averages can be overlaid and compared directly on-line. Data processing can be applied and those optimized parameters can be saved for off-line application.</p>
<p>Impedance testing is available without interrupting data acquisition, and is provided in a simple visual display with values for each electrode.</p>
<p>Stream live to Matlab or via TCP/IP protocol (listener CURRY, Matlab, custom software), suitable for Brain Computer Interface (BCI) and related applications.</p>
<p>The start and stop of recording, and the impedance test procedure can be controlled through the stimulus presentation software.</p>
<p>CURRY data files are compatible with EEGLAB.</p>
<p>Convert recordings into other formats (such as EDF or CNT) from within the acquisition software.</p>
<p><a href="https://compumedicsneuroscan.com/wp-content/uploads/CURRY-Package-Information-Card-2023.pdf">CURRY Package Information Card</a></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>CURRY 9 S &#8211; Signal Processing</title>
		<link>https://compumedicsneuroscan.com/product/curry-9-s-signal-processing/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Thu, 23 Dec 2021 15:41:14 +0000</pubDate>
				<guid isPermaLink="false">https://compumedicsneuroscan.com/?post_type=product&#038;p=7502</guid>

					<description><![CDATA[CURRY 9 Signal Processing (S)]]></description>
										<content:encoded><![CDATA[<p>The CURRY Signal Processing Package provides all the tools for processing your EEG, MEG data. After re-referencing, baseline correction, filtering, artifact detection and rejection, noise estimation, and selective averaging, CURRY can perform principal (PCA, SVD) or Independent Component Analyses (ICA) to visualize the spatio-temporal features of EEG and MEG data. A full suite of event editing and detection tools is available.</p>
<p>Template matching and threshold based event detection. Artifact reduction by subtraction and projection of averaged artifacts. Maps (equipotential contour lines), Source Current Density (Laplacians) and sensor coherences can be computed. Frequency domain analyses (FFT, Short Time FFT, Wavelets) are also possible.</p>
<p>CURRY uses a database structure that allows for optimized data management. Within the database, subjects can inherit the parent’s parameters, allowing automated processing to be built in to the database. Additionally, CURRY Macros can be developed to handle virtually any processing task, complete with the ability to design interactive and tutorial programs.</p>
<p><a href="https://compumedicsneuroscan.com/wp-content/uploads/CURRY-Package-Information-Card-2023.pdf">CURRY Package Information Card</a></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>CURRY 9 D &#8211; Digitizer</title>
		<link>https://compumedicsneuroscan.com/product/curry-9-d-digitizer/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Thu, 23 Dec 2021 15:05:37 +0000</pubDate>
				<guid isPermaLink="false">https://compumedicsneuroscan.com/?post_type=product&#038;p=7500</guid>

					<description><![CDATA[CURRY 9 Digitizer Package (D)]]></description>
										<content:encoded><![CDATA[<p>The Digitizer Package of CURRY 9 has been designed especially for those users that would like to use Curry for control of of their digitizer. The package allows the user to control the digitizer (various types of hardware supported), to capture the electrode positions on 3D, and to store those positions in a text file.</p>
<p><a href="https://compumedicsneuroscan.com/wp-content/uploads/CURRY-Package-Information-Card-2023.pdf">CURRY Package Information Card</a></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>128-channels Quik-Cap Hydro Net &#8211; Grael</title>
		<link>https://compumedicsneuroscan.com/product/128-channels-quik-cap-hydro-net-grael/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Tue, 15 Jan 2019 14:52:05 +0000</pubDate>
				<guid isPermaLink="false">https://compumedicsneuroscan.com/?post_type=product&#038;p=6368</guid>

					<description><![CDATA[The 128-channel Quik-Cap Hydro Net for the Grael amplifier is a high-density EEG cap with 2 integrated bipolar leads for vertical and horizontal EOG (VEOG, HEOG), ECG and EMG.

The cap connects directly to the Grael. The layout of the cap is according to the extended 10/20 system.]]></description>
										<content:encoded><![CDATA[<p>Compumedics Neuroscan offers a variety of Quik-Caps to provide speedy, consistent application of up to 256 electrodes. Quik-Caps Hydro Nets are manufactured of silicone material with sponges for enhanced patient comfort. A saline solution is used for a quick application without any abrasion. Setting up 64 or even more channels takes less than 5 minutes. All electrodes are placed according to the International 10-20 electrode placement standard.</p>
<p>Quik-Cap Hydro Nets are available in a variety of electrode configurations from 32 to 256 channels as well as in different sizes to meet every lab requirement.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>32-channels Quik-Cap Hydro Net &#8211; Grael</title>
		<link>https://compumedicsneuroscan.com/product/32-channels-quik-cap-hydro-net-grael/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Tue, 15 Jan 2019 14:51:58 +0000</pubDate>
				<guid isPermaLink="false">https://compumedicsneuroscan.com/?post_type=product&#038;p=6360</guid>

					<description><![CDATA[The 32-channel Quik-Cap Hydro Net for the Grael amplifier is a high-density EEG cap with 2 integrated bipolar leads for vertical and horizontal EOG (VEOG, HEOG), ECG and EMG.

The cap connects directly to the Grael. The layout of the cap is according to the extended 10/20 system.]]></description>
										<content:encoded><![CDATA[<p>Compumedics Neuroscan offers a variety of Quik-Caps to provide speedy, consistent application of up to 256 electrodes. Quik-Caps Hydro Nets are manufactured of silicone material with sponges for enhanced patient comfort. A saline solution is used for a quick application without any abrasion. Setting up 64 or even more channels takes less than 5 minutes. All electrodes are placed according to the International 10-20 electrode placement standard.</p>
<p>Quik-Cap Hydro Nets are available in a variety of electrode configurations from 32 to 256 channels as well as in different sizes to meet every lab requirement.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>64-channels Quik-Cap Hydro Net &#8211; Grael</title>
		<link>https://compumedicsneuroscan.com/product/64-channels-quik-cap-hydro-net-grael/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Tue, 15 Jan 2019 14:36:51 +0000</pubDate>
				<guid isPermaLink="false">https://compumedicsneuroscan.com/?post_type=product&#038;p=6350</guid>

					<description><![CDATA[The 64-channel Quik-Cap Hydro Net for the Grael amplifier is a high-density EEG cap with 2 integrated bipolar leads for vertical and horizontal EOG (VEOG, HEOG), ECG and EMG.

The cap connects directly to the Grael. The layout of the cap is according to the extended 10/20 system.]]></description>
										<content:encoded><![CDATA[<p>Compumedics Neuroscan offers a variety of Quik-Caps to provide speedy, consistent application of up to 256 electrodes. Quik-Caps Hydro Nets are manufactured of silicone material with sponges for enhanced patient comfort. A saline solution is used for a quick application without any abrasion. Setting up 64 or even more channels takes less than 5 minutes. All electrodes are placed according to the International 10-20 electrode placement standard.</p>
<p>Quik-Cap Hydro Nets are available in a variety of electrode configurations from 32 to 256 channels as well as in different sizes to meet every lab requirement.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>128-channels Quik-Cap Silicone Array &#8211; Grael</title>
		<link>https://compumedicsneuroscan.com/product/128-channels-quik-cap-silicone-array-grael/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Tue, 15 Jan 2019 14:29:39 +0000</pubDate>
				<guid isPermaLink="false">https://compumedicsneuroscan.com/?post_type=product&#038;p=6343</guid>

					<description><![CDATA[The 128-channel Quik-Cap Silicone Array for the Grael amplifier is a high-density EEG cap with 2 integrated bipolar leads for vertical and horizontal EOG (VEOG, HEOG), ECG and EMG.

The cap connects directly to the Grael amplifier. The layout of the cap is according to the extended 10/20 system.]]></description>
										<content:encoded><![CDATA[<p>Compumedics Neuroscan offers a variety of Quik-Caps to provide speedy, consistent application of up to 256 electrodes. Quik-Caps Silicone Array are manufactured of silicone material with soft electrode gel reservoirs for enhanced patient comfort. All electrodes are placed according to the International 10-20 electrode placement standard.</p>
<p>Quik-Cap Silicone Array caps are available in a variety of electrode configurations from 32 to 256 channels as well as in different sizes to meet every lab requirement.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>32-channels Quik-Cap Silicone Array &#8211; Grael</title>
		<link>https://compumedicsneuroscan.com/product/32-channels-quik-cap-silicone-array-grael/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Tue, 15 Jan 2019 14:29:28 +0000</pubDate>
				<guid isPermaLink="false">https://compumedicsneuroscan.com/?post_type=product&#038;p=6336</guid>

					<description><![CDATA[The 32-channel Quik-Cap Silicone Array for the Grael amplifier is a high-density EEG cap with 2 integrated bipolar leads for vertical and horizontal EOG (VEOG, HEOG), ECG and EMG.

The cap connects directly to the Grael amplifier. The layout of the cap is according to the extended 10/20 system.]]></description>
										<content:encoded><![CDATA[<p>Compumedics Neuroscan offers a variety of Quik-Caps to provide speedy, consistent application of up to 256 electrodes. Quik-Caps Silicone Array are manufactured of silicone material with soft electrode gel reservoirs for enhanced patient comfort. All electrodes are placed according to the International 10-20 electrode placement standard.</p>
<p>Quik-Cap Silicone Array caps are available in a variety of electrode configurations from 32 to 256 channels as well as in different sizes to meet every lab requirement.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
