<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>EEG &amp; fMRI &#8211; Compumedics Neuroscan</title>
	<atom:link href="https://compumedicsneuroscan.com/applications/eeg-fmri/feed/" rel="self" type="application/rss+xml" />
	<link>https://compumedicsneuroscan.com</link>
	<description>World Leader in Functional Neuro-imaging</description>
	<lastBuildDate>Thu, 10 Apr 2025 09:29:11 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	
	<item>
		<title>CURRY 9 X &#8211; Data Acquisition and Online Processing</title>
		<link>https://compumedicsneuroscan.com/product/curry-9-x-data-acquisition-and-online-processing/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Thu, 23 Dec 2021 15:45:10 +0000</pubDate>
				<guid isPermaLink="false">https://compumedicsneuroscan.com/?post_type=product&#038;p=7503</guid>

					<description><![CDATA[The CURRY 9 X Data Acquisition package is an easy-to-use and reliable tool for EEG data recording and online processing. All the features required for data acquisition are supported; for instance impedance check, online filtering, real-time event averaging, real-time fMRI/TMS artefact correction and many more. Using the TCP/IP interface, data is immediately available to other packages (for instance Matlab) and allows for BCI applications.

CURRY data files are fully compatible with EEGLAB.]]></description>
										<content:encoded><![CDATA[<p>The CURRY Neuroimaging Suite software is divided into several modules that can stand alone or work together to maximize your lab’s flexibility. The Acquire and Online Signal Processing package consists of all primary features and functions needed for acquiring high-quality EEG/EP/ERP data and online/real-time processing.</p>
<p>Acquisition in CURRY is enhanced with easier, more flexible, and more advanced tools for on-line data processing, with up to 512 channels and sampling rates up to 20 kHz.</p>
<p>CURRY will support EEG data acquisition with <a href="/products/by-name/synamps-2-rt/">SynAmps 2/RT</a>, <a href="http://compumedicsneuroscan.com/product/siesta-wireless-eeg-amplifier/">Siesta</a>, NuAmps, <a href="/products/by-name/neuvo/">Neuvo</a>, <a href="/products/by-name/grael/">Grael</a>, and E-Series <a href="/products/amplifiers/">amplifiers</a>. Each amplifier has its own set-up image to ensure ease of use in setting the system.</p>
<p>Online Artifact Reduction for up to five types of artifact can be applied simultaneously, letting you verify the quality of the data while the subject is still connected. Artifacts include blinks, pulse artifact, MR gradient artifact, ballistocardiogram, and bad blocks. Reduction methods include Subtraction, Covariance, PCA, and ICA.</p>
<p>On-line averaging is enhanced, with the ability to extract both standard TTL triggered and conditional averages. Averages can be overlaid and compared directly on-line. Data processing can be applied and those optimized parameters can be saved for off-line application.</p>
<p>Impedance testing is available without interrupting data acquisition, and is provided in a simple visual display with values for each electrode.</p>
<p>Stream live to Matlab or via TCP/IP protocol (listener CURRY, Matlab, custom software), suitable for Brain Computer Interface (BCI) and related applications.</p>
<p>The start and stop of recording, and the impedance test procedure can be controlled through the stimulus presentation software.</p>
<p>CURRY data files are compatible with EEGLAB.</p>
<p>Convert recordings into other formats (such as EDF or CNT) from within the acquisition software.</p>
<p><a href="https://compumedicsneuroscan.com/wp-content/uploads/CURRY-Package-Information-Card-2023.pdf">CURRY Package Information Card</a></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>128-channels fMRI Compatible Quik-Cap</title>
		<link>https://compumedicsneuroscan.com/product/128-channels-fmri-compatible-quik-cap/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Tue, 13 Dec 2016 15:57:47 +0000</pubDate>
				<guid isPermaLink="false">http://compumedicsneuroscan.com/product/128-channels-micro-maglink-quik-cap-copy/</guid>

					<description><![CDATA[The 128-channel Micro Maglink Quik-Cap has been specially designed for noise free and reliable concurrent EEG/fMRI recordings. The cap is equipped with integrated safety resistors and additional EOG and ECG bipolar leads.

The cap connects directly to the <a href="http://compumedicsneuroscan.com/product/micro-maglink-rt-eeg-fmri-eeg-meg/">Micro Maglink system</a>. The layout of the cap is according to the extended 10/20 system.]]></description>
										<content:encoded><![CDATA[<p>Compumedics Neuroscan offers a variety of Quik-Caps to provide speedy, consistent application of up to 256 electrodes. Quik-Caps are manufactured of highly elastic breathable Lycra material with soft neoprene electrode gel reservoirs for enhanced patient comfort. All electrodes are placed according to the International 10-20 electrode placement standard.</p>
<p>Quik-Caps are available in a variety of electrode configurations from 12 to 256 channels as well as in different sizes to meet every lab requirement.</p>
<p>Compumedics Neuroscan strongly recommends the use of Ag/Ag/Cl &#8211; sintered electrodes because of their durability and ease of cleaning and re-use. Each cap offering is designed to cover a specific range of sizes. Please specify the range you require.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>64-channels fMRI Compatible Quik-Cap</title>
		<link>https://compumedicsneuroscan.com/product/64-channels-fmri-compatible-quik-cap/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Tue, 13 Dec 2016 15:48:26 +0000</pubDate>
				<guid isPermaLink="false">http://compumedicsneuroscan.com/product/64-channels-micro-maglink-quik-cap/</guid>

					<description><![CDATA[The 64-channel Micro Maglink Quik-Cap has been specially designed for noise free and reliable concurrent EEG/fMRI recordings. The cap is equipped with integrated safety resistors and additional EOG and ECG bipolar leads.

The cap connects directly to the <a href="http://compumedicsneuroscan.com/product/micro-maglink-rt-eeg-fmri-eeg-meg/">Micro Maglink system</a>. The layout of the cap is according to the extended 10/20 system.]]></description>
										<content:encoded><![CDATA[<p>Compumedics Neuroscan offers a variety of Quik-Caps to provide speedy, consistent application of up to 256 electrodes. Quik-Caps are manufactured of highly elastic breathable Lycra material with soft neoprene electrode gel reservoirs for enhanced patient comfort. All electrodes are placed according to the International 10-20 electrode placement standard.</p>
<p>Quik-Caps are available in a variety of electrode configurations from 12 to 256 channels as well as in different sizes to meet every lab requirement.</p>
<p>Compumedics Neuroscan strongly recommends the use of Ag/Ag/Cl &#8211; sintered electrodes because of their durability and ease of cleaning and re-use. Each cap offering is designed to cover a specific range of sizes. Please specify the range you require.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MicroMagLink RT for EEG/fMRI and EEG/MEG</title>
		<link>https://compumedicsneuroscan.com/product/micro-maglink-rt-eeg-fmri-eeg-meg/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Mon, 07 Nov 2016 10:53:14 +0000</pubDate>
				<guid isPermaLink="false">http://compumedicsneuroscan.com/?post_type=product&#038;p=5488</guid>

					<description><![CDATA[For recording EEG in the MRI environment, nothing surpasses the <strong>MicroMagLink RT System</strong>.

The new MicroMagLink system is used for obtaining integrated EEG and EP/ERP recordings inside the fMRI and MEG. The passive MicroMagLink system provides the ability to record during the pulse sequence without compromising the raw EEG data. 

The MicroMagLink, in conjunction with Neuroscan amplifiers has successfully recorded EEG data through the pulse sequence in up to 3 Tesla MRI scanners. The <strong>CURRY</strong> Acquisition and Signal Processing package provide powerful features for on-line and off-line reduction of the ballistocardiogram and pulse sequence artifact, while retaining the integrity of the EEG. Post-processing tools allow ERP’s to be extracted, which can then be subjected to source localization and compared with the fMRI.]]></description>
										<content:encoded><![CDATA[<p>Built upon the core <strong>SynAmps RT</strong> amplifier, the <strong>MicroMagLink RT</strong> System provides an impressive solution with several critical advantages:</p>
<ul>
<li>No electronics in the MRI room to interfere with the static or gradient field; Neuroscan MicroMagLink RT systems have been proven in up to 4 Tesla systems.</li>
<li>Compatible with most waveguide panel designs for easier installation with minimal modifications.</li>
<li>All signal processing occurs outside the MRI room, preserving signal quality without compromises for MRI-compatible electronic design.</li>
<li>Up to 20,000Hz sampling rates, allowing adequate sampling of the fastest frequencies.</li>
<li>Multiple, advanced algorithms for artifact removal; user selectable and modifiable.</li>
<li>SynAmps RT amplifiers provide DC-coupled recordings to ensure fast recovery from artifacts.</li>
<li>SynAmps RT supports integration with the MRI clock to synchronize MRI and EEG samples, allowing improved artifact reduction, real-time artifact reduction, and acquisition with conventional sampling rates (500 and 1000Hz).</li>
<li>Both ECG and plethysmography signals are recorded by the system, to optimally remove the ballistocardiogram artifact.</li>
<li>On-line correction of pulse sequence artifact, allows you to view corrected data in near real time.</li>
<li>Includes the advantages of the CURRY software platform with advanced signal processing and image integration.</li>
<li>Compatible with most stimulus presentation systems providing a TTL or synchronization pulse output, enabling acquisition of ERPs simultaneous with the MRI.</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SynAmps RT 256-channel Amplifier</title>
		<link>https://compumedicsneuroscan.com/product/synamps-rt-256-channel-eeg-erp-ep-amplifier/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Tue, 25 Oct 2016 07:13:00 +0000</pubDate>
				<guid isPermaLink="false">http://compumedicsneuroscan.com/product/synamps-rt-256-channel-amplifier/</guid>

					<description><![CDATA[<strong>SynAmps RT</strong> is the one of the latest EEG, ERP and EP amplifier from Compumedics Neuroscan. Using the most current technology, the RT builds on the quality of the past SynAmps series of amplifiers and extends the specifications beyond anything that has come before.

<strong>SynAmps RT</strong> sets a new standard in amplifier technology, providing a system suitable for recording everything from high sampling rate (20,000 Hz) Auditory Brain Stem recordings and Spike Spindles to true DC recordings of CNV and P300.

The <strong>SynAmps RT</strong> also serves as the recommended platform for recording in the MRI and MEG, in conjunction with the <strong>Micro MagLink RT</strong> system. SynAmps RT includes clock synchronization circuitry, allowing the amplifier to synch with other devices, such as MR scanners, more precisely, without the need for very fast acquisition rates.

<strong>SynAmps RT</strong> can be used in conjunction with the <strong>CURRY</strong> software, providing a complete acquisition and analysis system, or with the ACCESS SDK, allowing user’s custom built software to control and acquire data from the system.

<strong>SynAmps RT</strong> can also be used with the <strong>STIM2</strong> system for integrated and accurate stimulus presentation or will accept TTL pulses from third party systems.

<strong>SynAmps RT</strong> can be used with the <strong>QuikCap</strong>, to provide fast and simple electrode placement or will accept any touch proof electrode as well. Grid, depth and microelectrodes may also be used with the SynAmps RT.

The <strong>SynAmps RT</strong> system has CE Class IIa medical certification and FDA approval.]]></description>
										<content:encoded><![CDATA[<p><strong>Channel Count Per Headbox: 64 Monopolar, 4 Bipolar, 2 High Level</strong><br />
Utilizing the latest technology, SynAmps RT allows for discrete monopolar and bipolar channels, enhancing the flexibility of recordings. Additional high level inputs are isolated to allow voltage level signals to be merged with the physiological data. Linking headboxes together allows more than 500 channels to be recorded.</p>
<p><span style="text-decoration: underline;">A 256-channel SynAmps RT EEG system consists of four headboxes, with 280 channels in total</span>.</p>
<p>A fully isolated, programmable bipolar excitation supply is also provided capable of supplying up to +/- 10VDC at 100mA to external bridges or measurement devices.</p>
<p><strong>Maximum Sampling Rate: 20,000 Per Channel all channels driven</strong><br />
Faster sampling rates allow for more accurate sampling of the analog data being recorded. Signals such as Auditory Brain Stem Response require these faster rates, while typical ERP measures benefit from increased resolution.</p>
<p><strong>Sampling Method: All Channels Sampled Simultaneously</strong><br />
Current technology eliminates the problems associated with sample and hold circuits. Utilizing a dedicated 24-bit A to D chip for each channel, the SynAmps RT enhances resolution and accuracy of each sample by ensuring a more valid measure of the data without decay or skew.</p>
<p>The 24-bit resolution allows for even the most subtle differences in amplitude to be measured accurately.</p>
<p><strong>Recording Bandwidth: DC to 3500 Hz</strong><br />
Many slow potentials (i.e., P300, MMN, CNV) have components that can only be measured accurately using a DC amplifier. DC amplifiers are also not subject to the AC coupled, filter time constant that distorts recordings after an artifact. The high frequency end of the SynAmps RT&#8217;s range allows for more accurate recording of the fastest frequencies.</p>
<p><strong>Active Noise Cancellation: Utilizing advanced driven reference technology</strong><br />
SynAmps RT sets a new standard for amplifier design, both in terms of safety and signal quality. Actively sampling environmental noise, and applying an antiphase signal to eliminate that noise, elevates the CMRR to unprecedented levels. This technology also provides increased patient protection.</p>
<p><strong>Recording in fMRI Environments: Integration with the Micro MagLink RT System</strong><br />
The same amplifier that is used in standard recording environments can also be used to record EEG data in the MRI by interfacing to the Micro MagLink RT system. SynAmps RT was built with enough input range and accuracy to sample both the EEG and the fMRI artifact with sufficient resolution to remove the artifact and ensure the EEG is left intact.</p>
<p><strong>&gt;10 G Ohm Input Impedance: Allows standard impedance or fast preparation to be obtained</strong><br />
SynAmps RT allows you to choose on a subject by subject basis to prepare the scalp electrode impedance to the scientifically accepted levels or to record with high impedance, due to time or subject constraints. This flexibility allows you the option to maximize your data collection for each subject and collect the best data the situation allows.</p>
<p><strong>Portability and Integration: Small Package, big features</strong><br />
Digital amplifiers are typically small and thus portable, but portability also means unpredictable environmental noise. SynAmps RT has built in technology to function even in the worst electromagnetic fields. Custom solutions such as Mu metal shielding are available to ensure data quality even under hostile conditions.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SynAmps RT 128-channel Amplifier</title>
		<link>https://compumedicsneuroscan.com/product/synamps-rt-128-channel-eeg-erp-ep-amplifier/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Tue, 25 Oct 2016 07:06:18 +0000</pubDate>
				<guid isPermaLink="false">http://compumedicsneuroscan.com/product/synamps-rt-128-channel-amplifier/</guid>

					<description><![CDATA[<strong>SynAmps RT</strong> is the one of the latest EEG, ERP and EP amplifier from Compumedics Neuroscan. Using the most current technology, the RT builds on the quality of the past SynAmps series of amplifiers and extends the specifications beyond anything that has come before.

<strong>SynAmps RT</strong> sets a new standard in amplifier technology, providing a system suitable for recording everything from high sampling rate (20,000 Hz) Auditory Brain Stem recordings and Spike Spindles to true DC recordings of CNV and P300.

The <strong>SynAmps RT</strong> also serves as the recommended platform for recording in the MRI and MEG, in conjunction with the <strong>Micro MagLink RT</strong> system. SynAmps RT includes clock synchronization circuitry, allowing the amplifier to synch with other devices, such as MR scanners, more precisely, without the need for very fast acquisition rates.

<strong>SynAmps RT</strong> can be used in conjunction with the <strong>CURRY</strong> software, providing a complete acquisition and analysis system, or with the ACCESS SDK, allowing user’s custom built software to control and acquire data from the system.

<strong>SynAmps RT</strong> can also be used with the <strong>STIM2</strong> system for integrated and accurate stimulus presentation or will accept TTL pulses from third party systems.

<strong>SynAmps RT</strong> can be used with the <strong>QuikCap</strong>, to provide fast and simple electrode placement or will accept any touch proof electrode as well. Grid, depth and microelectrodes may also be used with the SynAmps RT.

The <strong>SynAmps RT</strong> system has CE Class IIa medical certification and FDA approval.]]></description>
										<content:encoded><![CDATA[<p><strong>Channel Count Per Headbox: 64 Monopolar, 4 Bipolar, 2 High Level</strong><br />
Utilizing the latest technology, SynAmps RT allows for discrete monopolar and bipolar channels, enhancing the flexibility of recordings. Additional high level inputs are isolated to allow voltage level signals to be merged with the physiological data. Linking headboxes together allows more than 500 channels to be recorded.</p>
<p><span style="text-decoration: underline;">A 128-channel SynAmps RT EEG system consists of two headboxes, with 140 channels in total</span>.</p>
<p>A fully isolated, programmable bipolar excitation supply is also provided capable of supplying up to +/- 10VDC at 100mA to external bridges or measurement devices.</p>
<p><strong>Maximum Sampling Rate: 20,000 Per Channel all channels driven</strong><br />
Faster sampling rates allow for more accurate sampling of the analog data being recorded. Signals such as Auditory Brain Stem Response require these faster rates, while typical ERP measures benefit from increased resolution.</p>
<p><strong>Sampling Method: All Channels Sampled Simultaneously</strong><br />
Current technology eliminates the problems associated with sample and hold circuits. Utilizing a dedicated 24-bit A to D chip for each channel, the SynAmps RT enhances resolution and accuracy of each sample by ensuring a more valid measure of the data without decay or skew.</p>
<p>The 24-bit resolution allows for even the most subtle differences in amplitude to be measured accurately.</p>
<p><strong>Recording Bandwidth: DC to 3500 Hz</strong><br />
Many slow potentials (i.e., P300, MMN, CNV) have components that can only be measured accurately using a DC amplifier. DC amplifiers are also not subject to the AC coupled, filter time constant that distorts recordings after an artifact. The high frequency end of the SynAmps RT&#8217;s range allows for more accurate recording of the fastest frequencies.</p>
<p><strong>Active Noise Cancellation: Utilizing advanced driven reference technology</strong><br />
SynAmps RT sets a new standard for amplifier design, both in terms of safety and signal quality. Actively sampling environmental noise, and applying an antiphase signal to eliminate that noise, elevates the CMRR to unprecedented levels. This technology also provides increased patient protection.</p>
<p><strong>Recording in fMRI Environments: Integration with the Micro MagLink RT System</strong><br />
The same amplifier that is used in standard recording environments can also be used to record EEG data in the MRI by interfacing to the Micro MagLink RT system. SynAmps RT was built with enough input range and accuracy to sample both the EEG and the fMRI artifact with sufficient resolution to remove the artifact and ensure the EEG is left intact.</p>
<p><strong>&gt;10 G Ohm Input Impedance: Allows standard impedance or fast preparation to be obtained</strong><br />
SynAmps RT allows you to choose on a subject by subject basis to prepare the scalp electrode impedance to the scientifically accepted levels or to record with high impedance, due to time or subject constraints. This flexibility allows you the option to maximize your data collection for each subject and collect the best data the situation allows.</p>
<p><strong>Portability and Integration: Small Package, big features</strong><br />
Digital amplifiers are typically small and thus portable, but portability also means unpredictable environmental noise. SynAmps RT has built in technology to function even in the worst electromagnetic fields. Custom solutions such as Mu metal shielding are available to ensure data quality even under hostile conditions.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SynAmps RT 64-channel Amplifier</title>
		<link>https://compumedicsneuroscan.com/product/synamps-rt-64-channel-eeg-erp-ep-amplifier/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Mon, 24 Oct 2016 15:21:23 +0000</pubDate>
				<guid isPermaLink="false">http://compumedicsneuroscan.com/?post_type=product&#038;p=5269</guid>

					<description><![CDATA[<strong>SynAmps RT</strong> is the one of the latest EEG, ERP and EP amplifier from Compumedics Neuroscan. Using the most current technology, the RT builds on the quality of the past SynAmps series of amplifiers and extends the specifications beyond anything that has come before.

<strong>SynAmps RT</strong> sets a new standard in amplifier technology, providing a system suitable for recording everything from high sampling rate (20,000 Hz) Auditory Brain Stem recordings and Spike Spindles to true DC recordings of CNV and P300.

The <strong>SynAmps RT</strong> also serves as the recommended platform for recording in the MRI and MEG, in conjunction with the <strong>Micro MagLink RT</strong> system. SynAmps RT includes clock synchronization circuitry, allowing the amplifier to synch with other devices, such as MR scanners, more precisely, without the need for very fast acquisition rates.

<strong>SynAmps RT</strong> can be used in conjunction with the <strong>CURRY</strong> software, providing a complete acquisition and analysis system, or with the ACCESS SDK, allowing user’s custom built software to control and acquire data from the system.

<strong>SynAmps RT</strong> can also be used with the <strong>STIM2</strong> system for integrated and accurate stimulus presentation or will accept TTL pulses from third party systems.

<strong>SynAmps RT</strong> can be used with the <strong>QuikCap</strong>, to provide fast and simple electrode placement or will accept any touch proof electrode as well. Grid, depth and microelectrodes may also be used with the SynAmps RT.

The <strong>SynAmps RT</strong> system has CE Class IIa medical certification and FDA approval.]]></description>
										<content:encoded><![CDATA[<p><strong>Channel Count Per Headbox: 64 Monopolar, 4 Bipolar, 2 High Level</strong><br />
Utilizing the latest technology, SynAmps RT allows for discrete monopolar and bipolar channels, enhancing the flexibility of recordings. Additional high level inputs are isolated to allow voltage level signals to be merged with the physiological data. Linking headboxes together allows more than 500 channels to be recorded.</p>
<p><span style="text-decoration: underline;">A 64-channel SynAmps RT EEG system has one headbox, with 70 channels in total</span>.</p>
<p>A fully isolated, programmable bipolar excitation supply is also provided capable of supplying up to +/- 10VDC at 100mA to external bridges or measurement devices.</p>
<p><strong>Maximum Sampling Rate: 20,000 Per Channel all channels driven</strong><br />
Faster sampling rates allow for more accurate sampling of the analog data being recorded. Signals such as Auditory Brain Stem Response require these faster rates, while typical ERP measures benefit from increased resolution.</p>
<p><strong>Sampling Method: All Channels Sampled Simultaneously</strong><br />
Current technology eliminates the problems associated with sample and hold circuits. Utilizing a dedicated 24-bit A to D chip for each channel, the SynAmps RT enhances resolution and accuracy of each sample by ensuring a more valid measure of the data without decay or skew.</p>
<p>The 24-bit resolution allows for even the most subtle differences in amplitude to be measured accurately.</p>
<p><strong>Recording Bandwidth: DC to 3500 Hz</strong><br />
Many slow potentials (i.e., P300, MMN, CNV) have components that can only be measured accurately using a DC amplifier. DC amplifiers are also not subject to the AC coupled, filter time constant that distorts recordings after an artifact. The high frequency end of the SynAmps RT&#8217;s range allows for more accurate recording of the fastest frequencies.</p>
<p><strong>Active Noise Cancellation: Utilizing advanced driven reference technology</strong><br />
SynAmps RT sets a new standard for amplifier design, both in terms of safety and signal quality. Actively sampling environmental noise, and applying an antiphase signal to eliminate that noise, elevates the CMRR to unprecedented levels. This technology also provides increased patient protection.</p>
<p><strong>Recording in fMRI Environments: Integration with the Micro MagLink RT System</strong><br />
The same amplifier that is used in standard recording environments can also be used to record EEG data in the MRI by interfacing to the Micro MagLink RT system. SynAmps RT was built with enough input range and accuracy to sample both the EEG and the fMRI artifact with sufficient resolution to remove the artifact and ensure the EEG is left intact.</p>
<p><strong>&gt;10 G Ohm Input Impedance: Allows standard impedance or fast preparation to be obtained</strong><br />
SynAmps RT allows you to choose on a subject by subject basis to prepare the scalp electrode impedance to the scientifically accepted levels or to record with high impedance, due to time or subject constraints. This flexibility allows you the option to maximize your data collection for each subject and collect the best data the situation allows.</p>
<p><strong>Portability and Integration: Small Package, big features</strong><br />
Digital amplifiers are typically small and thus portable, but portability also means unpredictable environmental noise. SynAmps RT has built in technology to function even in the worst electromagnetic fields. Custom solutions such as Mu metal shielding are available to ensure data quality even under hostile conditions.</p>